GENERAL PROCEDURES
NOTICE
These general procedures will be referenced in other sections throughout the manual.
SETUP JUMPER INSTALLATION
NOTICE
Machine must be secured prior to installation. Installing setup jumper will:
•Disable Cold Start
•Increase Engine RPM to Full operating RPM
•Disable Stroke Follower
1.Remove Cap (P\N: 22812) on P24 of main harness (under foot platform).
2.Install Setup Jumper (P/N: 32007 on P24).
REMOVE SETUP JUMPER (If installed).
1.Remove Setup Jumper (P\N: 32007) from P24 of main harness.
2.
Table 2. Disable and Re-enable Options
|
| 1. | Open service tool. |
|
| 2. | Click “machine setup” button on main page. |
| Cold Start | 3. | Click “Cold Start” button under Setup Menu. |
DISABLE |
| 4. | Click check box next to Disabled. |
(If Setup Jumper is not |
| 5. | Press Download Button. |
installed) |
| 1. | Open service tool. |
| Stroke Follower | 2. | Click “machine setup” button on main page. |
| 3. | Click “Stroke Cont.” button under Setup Menu. | |
|
| ||
|
| 4. | Click button “Disable Stroke Follower”. |
|
| 1. | Open service tool. |
|
| 2. | Click “machine setup” button on main page. |
| Cold Start | 3. | Click “Cold Start” button under Setup Menu. |
|
| 4. | Uncheck box next to Disable. |
|
|
|
|
(If disabled via service |
| 5. | Press Download Button. |
tool) |
| 1. | Open service tool. |
| Stroke Follower | 2. | Click “machine setup” button on main page. |
| 3. | Click “Stroke Cont.” button under Setup Menu. | |
|
| ||
|
| 4. | Click button “Enable Stroke Follower”. |
PAGE 12 — HTXD6i/STXD6i TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #1 (01/24/14)