Multiquip HTXD6i / STXD6i manual General Procedures, Setup Jumper Installation

Page 12

GENERAL PROCEDURES

NOTICE

These general procedures will be referenced in other sections throughout the manual.

SETUP JUMPER INSTALLATION

NOTICE

Machine must be secured prior to installation. Installing setup jumper will:

Disable Cold Start

Increase Engine RPM to Full operating RPM

Disable Stroke Follower

1.Remove Cap (P\N: 22812) on P24 of main harness (under foot platform).

2.Install Setup Jumper (P/N: 32007 on P24).

REMOVE SETUP JUMPER (If installed).

1.Remove Setup Jumper (P\N: 32007) from P24 of main harness.

2.Re-install Cap (P\N: 22812) on P24 of main harness.

Table 2. Disable and Re-enable Options

 

 

1.

Open service tool.

 

 

2.

Click “machine setup” button on main page.

 

Cold Start

3.

Click “Cold Start” button under Setup Menu.

DISABLE

 

4.

Click check box next to Disabled.

(If Setup Jumper is not

 

5.

Press Download Button.

installed)

 

1.

Open service tool.

 

Stroke Follower

2.

Click “machine setup” button on main page.

 

3.

Click “Stroke Cont.” button under Setup Menu.

 

 

 

 

4.

Click button “Disable Stroke Follower”.

 

 

1.

Open service tool.

 

 

2.

Click “machine setup” button on main page.

 

Cold Start

3.

Click “Cold Start” button under Setup Menu.

RE-ENABLE

 

4.

Uncheck box next to Disable.

 

 

 

 

(If disabled via service

 

5.

Press Download Button.

tool)

 

1.

Open service tool.

 

Stroke Follower

2.

Click “machine setup” button on main page.

 

3.

Click “Stroke Cont.” button under Setup Menu.

 

 

 

 

4.

Click button “Enable Stroke Follower”.

PAGE 12 — HTXD6i/STXD6i TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #1 (01/24/14)

Image 12
Contents Model HTXD6i/STXD6i This Manual Must Accompany the Equipment AT ALL TimesTable of Contents HTX6Di/STX6Di TrowelMachine Information and Maintenance LOG Safety Information Safety MessagesGeneral Safety „ALWAYS know the location of the nearestTrowel Safety Engine SafetyOrder Form PT-160 Before servicing equipmentFuel Safety Battery Safety„ Never tamper with the factory settings „ Use well-insulated gloves when picking up the batteryTransporting Safety Towing SafetyLifting „ Always shutdown engine before transporting Environmental Safety Tools Needed Machine Information ModelSerial Number General Procedures Setup Jumper InstallationRemove Setup Jumper If installed Initial Check and Adjustments OIL and Coolant CheckHydraulic Oil Check Loosen 1-1/16 jam nut on charge relief valve Item A, FigureEngine Oil Engine CoolantEnsure engine is level Service Tool Setup and Connection Click Cancel again when the new screen comes upInput the license key obtained from Multiquip and click OK WST Tool BarLaptop Configuration Connection ProcedureClick Finish on the next screen to complete installation Necessary to crank or turn on the engineMachine Setup and Calibration Sensor AdjustmentCalibrate Foot Pedal Click Calibration button in Pedal Sensor frame FigureSecondary Hydraulic Fill Procedures CalibrationPress Start button to begin calibration and follow prompts Machine Pressure Adjustment Charge Pressure AdjustmentPitch Pressure Check Restart machinePitch Pressure Adjustment Steering Pressure AdjustmentReturn engine rpm to idle Turn off machine and remove gauge Trowel Speed ADJUSTMENT\SETUP Adjust Zero Stroke PositionLeft Side Trowel Speed Adjustment Lower trowel and shut off Loosen Jamb nut Item D, FigureRight Side Trowel Speed Adjustment Remove setup jumper or re-enable stroke followerCalibrate Stroke Sensor Pitch Setup Flatten BladesLeading Edge Height Adjustment Measure Blade Leading Edge HeightSet Zero Pitch Cylinder Stops Pitch Sensor CalibrationGauge Turn machine off for 10 secondsInspection Fluid LevelsMechanical Switch smart pitch switch to off position Static Blade Pitch Drift TestFuse Information Refer to for location on fuse panelPage HERE’S HOW to GET Help