TOOLS NEEDED

The specialized tools listed in Table 1 are required to maintain and service the HTXD6i and STXD6i ride-on trowels. Fleet technicians and servicing dealers must have these tools for efficient unit setup and component calibration.

Table 1. Setup, Calibration, and Diagnostic Tools

TOOL

DESCRIPTION

PART NO.

QTY

Tool Kit

Includes all tools listed below.

32062

1

 

Required to interface to the trowel MCU.

 

 

CAN Gateway Cable

Required for foot pedal calibration, pitch

22882

1

sync calibration, stroke cylinder calibration,

 

 

 

 

engine fault code reading, diagnostics, ETC.

 

 

 

Used in calibrating one of the two blade pitch

 

 

Gauge Tool (3.25”)

set points as part of the synchronization

32044

2

 

process.

 

 

 

Used in calibrating one of the two blade pitch

 

 

Gauge Tool (2.25”)

set points as part of the synchronization

32000

2

 

process.

 

 

 

Used to place the engine at full speed for

 

 

Set Up Jumper

component calibration and to simultaneously

32007

1

disable both the stroke follower and cold

 

 

 

 

start mode.

 

 

 

Used to help set the foot pedal sensor. It is

 

 

Pedal Wrench

also used for setting the Zero Pitch Cylinder

32020

1

 

Stops by using the thickness of the wrench.

 

 

PAGE 10 — HTXD6i/STXD6i TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #1 (01/24/14)

Image 10
Contents Model HTXD6i/STXD6i This Manual Must Accompany the Equipment AT ALL TimesTable of Contents HTX6Di/STX6Di TrowelMachine Information and Maintenance LOG Safety Information Safety MessagesGeneral Safety „ALWAYS know the location of the nearestOrder Form PT-160 Trowel SafetyEngine Safety Before servicing equipment „ Never tamper with the factory settings Fuel Safety Battery Safety „ Use well-insulated gloves when picking up the batteryLifting Transporting SafetyTowing Safety „ Always shutdown engine before transportingEnvironmental Safety Tools Needed Model Machine InformationSerial Number Setup Jumper Installation General ProceduresRemove Setup Jumper If installed Hydraulic Oil Check Initial Check and AdjustmentsOIL and Coolant Check Loosen 1-1/16 jam nut on charge relief valve Item A, FigureEngine Coolant Engine OilEnsure engine is level Service Tool Setup and Connection Click Cancel again when the new screen comes upInput the license key obtained from Multiquip and click OK WST Tool BarClick Finish on the next screen to complete installation Laptop ConfigurationConnection Procedure Necessary to crank or turn on the engineCalibrate Foot Pedal Machine Setup and CalibrationSensor Adjustment Click Calibration button in Pedal Sensor frame FigureCalibration Secondary Hydraulic Fill ProceduresPress Start button to begin calibration and follow prompts Pitch Pressure Check Machine Pressure AdjustmentCharge Pressure Adjustment Restart machineSteering Pressure Adjustment Pitch Pressure AdjustmentReturn engine rpm to idle Turn off machine and remove gauge Left Side Trowel Speed Adjustment Trowel Speed ADJUSTMENT\SETUPAdjust Zero Stroke Position Lower trowel and shut off Loosen Jamb nut Item D, FigureRemove setup jumper or re-enable stroke follower Right Side Trowel Speed AdjustmentCalibrate Stroke Sensor Pitch Setup Flatten BladesLeading Edge Height Adjustment Measure Blade Leading Edge HeightSet Zero Pitch Cylinder Stops Pitch Sensor CalibrationGauge Turn machine off for 10 secondsFluid Levels InspectionMechanical Switch smart pitch switch to off position Static Blade Pitch Drift TestFuse Information Refer to for location on fuse panelPage HERE’S HOW to GET Help