Multiquip HTXD6i / STXD6i manual Right Side Trowel Speed Adjustment, Calibrate Stroke Sensor

Page 23

MACHINE SETUP AND CALIBRATION

5.Re-measure speed, repeating steps 2 and 3 until Left Side Trowel Speed is correct:

a.HTXD6i — 157 to 160 RPM (942 to 960 Pulses per minute)

b.STXD6i— 127 to 130 RPM (762 to 780 Pulses per minute)

6.Record L.H. speed on Machine Information and Maintenance Log in machine setup area.

Right Side Trowel Speed Adjustment

NOTICE

Stroke sensor must be recalibrated after trowel speed adjustment for proper machine operation.

The trowel speeds should be adjusted on a dry concrete floor with the blades pitched slightly (tips about 1/2” off ground).

1.Verify setup jumper is installed or stroke follower is disabled.

2.Fully depress pedal, measure Left Side and Right Side Trowel Speed.

3.Adjust trowel arm connecting rod on the pump actuating lever and tighten jamb nuts (Figure 33).

Calibrate Stroke Sensor

CAUTION

Machine movement will occur during this step. Ensure machine is secure or operator is present in seat. All guards should be in place. Keep fingers, hands, hair, and clothing away from all moving parts to prevent injury.

1.Turn machine off for at least 10 seconds.

2.Restart machine.

3.Install Setup Jumper or disable Stroke Follower.

4.Click “Calibration” button on machine setup page.

5.Click “Calibration” button in STROKE SENSOR section (Figure 34).

Figure 34. Calibrate Stroke Sensor

Figure 33. Adjusting Right Side Trowel Speed

4.Re-measure speed and repeat steps 2 and 3 until Left Side and Right side are within 1 RPM of each other.

5.Record R.H. speed on Machine Information and Maintenance Log in Machine Setup section.

6.Remove setup jumper or re-enable stroke follower.

HTXD6i/STXD6i TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #1 (01/24/14) — PAGE 23

Image 23
Contents This Manual Must Accompany the Equipment AT ALL Times Model HTXD6i/STXD6iHTX6Di/STX6Di Trowel Table of ContentsMachine Information and Maintenance LOG Safety Messages Safety Information„ALWAYS know the location of the nearest General SafetyBefore servicing equipment Trowel SafetyEngine Safety Order Form PT-160„ Use well-insulated gloves when picking up the battery Fuel SafetyBattery Safety „ Never tamper with the factory settings„ Always shutdown engine before transporting Transporting SafetyTowing Safety LiftingEnvironmental Safety Tools Needed Serial Number Machine InformationModel Remove Setup Jumper If installed General ProceduresSetup Jumper Installation Loosen 1-1/16 jam nut on charge relief valve Item A, Figure Initial Check and AdjustmentsOIL and Coolant Check Hydraulic Oil CheckEnsure engine is level Engine OilEngine Coolant Click Cancel again when the new screen comes up Service Tool Setup and ConnectionWST Tool Bar Input the license key obtained from Multiquip and click OKNecessary to crank or turn on the engine Laptop ConfigurationConnection Procedure Click Finish on the next screen to complete installationClick Calibration button in Pedal Sensor frame Figure Machine Setup and CalibrationSensor Adjustment Calibrate Foot PedalPress Start button to begin calibration and follow prompts Secondary Hydraulic Fill ProceduresCalibration Restart machine Machine Pressure AdjustmentCharge Pressure Adjustment Pitch Pressure CheckReturn engine rpm to idle Turn off machine and remove gauge Pitch Pressure AdjustmentSteering Pressure Adjustment Lower trowel and shut off Loosen Jamb nut Item D, Figure Trowel Speed ADJUSTMENT\SETUPAdjust Zero Stroke Position Left Side Trowel Speed AdjustmentCalibrate Stroke Sensor Right Side Trowel Speed AdjustmentRemove setup jumper or re-enable stroke follower Flatten Blades Pitch SetupMeasure Blade Leading Edge Height Leading Edge Height AdjustmentPitch Sensor Calibration Set Zero Pitch Cylinder StopsTurn machine off for 10 seconds GaugeMechanical InspectionFluid Levels Static Blade Pitch Drift Test Switch smart pitch switch to off positionRefer to for location on fuse panel Fuse InformationPage HERE’S HOW to GET Help