Multiquip HTXD6i / STXD6i manual Static Blade Pitch Drift Test

Page 29

INSPECTION

STATIC BLADE PITCH DRIFT TEST

1.Switch smart pitch switch to off position.

2.Bring machine up to temperature.This will be indicated by “Cold Start” (aux 1) lamp turning off.

3.Choose one blade from each spider and mark with small X to identify.

4.Using the Twin pitch button, cycle the blades from flat to full pitch 8 times leaving the blades in the full pitch position on the eighth cycle.

5.Turn the engine off, and record time and tip height on Machine Information and Maintenance Log.

6.Leave for a 3-hour test period then re-measure tip height. Record height and time on Machine Information and Maintenance Log.

7.Compare the two measurements. Drift exceeding 3/16” in three hours is unacceptable.

HTXD6i/STXD6i TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #1 (01/24/14) — PAGE 29

Image 29
Contents This Manual Must Accompany the Equipment AT ALL Times Model HTXD6i/STXD6iHTX6Di/STX6Di Trowel Table of ContentsMachine Information and Maintenance LOG Safety Messages Safety Information„ALWAYS know the location of the nearest General SafetyEngine Safety Trowel SafetyOrder Form PT-160 Before servicing equipmentBattery Safety Fuel Safety„ Never tamper with the factory settings „ Use well-insulated gloves when picking up the batteryTowing Safety Transporting SafetyLifting „ Always shutdown engine before transportingEnvironmental Safety Tools Needed Serial Number Machine InformationModel Remove Setup Jumper If installed General ProceduresSetup Jumper Installation OIL and Coolant Check Initial Check and AdjustmentsHydraulic Oil Check Loosen 1-1/16 jam nut on charge relief valve Item A, FigureEnsure engine is level Engine OilEngine Coolant Click Cancel again when the new screen comes up Service Tool Setup and ConnectionWST Tool Bar Input the license key obtained from Multiquip and click OKConnection Procedure Laptop ConfigurationClick Finish on the next screen to complete installation Necessary to crank or turn on the engineSensor Adjustment Machine Setup and CalibrationCalibrate Foot Pedal Click Calibration button in Pedal Sensor frame FigurePress Start button to begin calibration and follow prompts Secondary Hydraulic Fill ProceduresCalibration Charge Pressure Adjustment Machine Pressure AdjustmentPitch Pressure Check Restart machineReturn engine rpm to idle Turn off machine and remove gauge Pitch Pressure AdjustmentSteering Pressure Adjustment Adjust Zero Stroke Position Trowel Speed ADJUSTMENT\SETUPLeft Side Trowel Speed Adjustment Lower trowel and shut off Loosen Jamb nut Item D, FigureCalibrate Stroke Sensor Right Side Trowel Speed AdjustmentRemove setup jumper or re-enable stroke follower Flatten Blades Pitch SetupMeasure Blade Leading Edge Height Leading Edge Height Adjustment Pitch Sensor Calibration Set Zero Pitch Cylinder StopsTurn machine off for 10 seconds GaugeMechanical InspectionFluid Levels Static Blade Pitch Drift Test Switch smart pitch switch to off positionRefer to for location on fuse panel Fuse InformationPage HERE’S HOW to GET Help