LAPTOP CONFIGURATION
CONNECTION PROCEDURE
NOTICE
Make sure that the Sauer Danfoss Plus Software and Whiteman Service Tool (WST) are installed before proceeding with the connection procedure.
1.Plug the CAN Gateway cable to the trowel at the service port (Figure 16). Do not connect laptop at this time.
4.When the CAN Gateway cable is connected to the laptop for the first time, it is necessary to install the CAN driver software. The installation screen will appear (Figure 19). Click "Next" to install the software automatically (default).
Figure 16. CAN Gateway Cable to Service Port
2.On the trowel, turn the ignition key to the ON position (Figure 17). This will turn on the MCU. It is not
necessary to crank or turn on the engine.
OFF
ACCON
CRANK
Figure 17. Ignition Key ON
3.Connect the USB connector of the CAN Gateway cable to the USB port (Figure 18).
Figure 18. Connecting the Laptop
Figure 19. CAN Driver Installation
5.Click "Finish" on the next screen (Figure 20) to complete installation.
Figure 20. CAN Driver Installation Complete
6.On the Service Tool software on your laptop, the main screen should show Firmware info loaded from trowel MCU and the Machine Status box shows lamps lit (Figure 21).
Figure 21. Service Tool Main Screen
HTXD6i/STXD6i TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #1 (01/24/14) — PAGE 17