ENGLISH
9. Technical Specifications
Suction capacity | l/min | 350 |
|
|
|
Free air delivery (volume flow rate) | l/min | 165 |
|
|
|
Filling rate | l/min | 200 |
|
|
|
Max. working pressure | bar | 8 |
|
|
|
Max. storage / operating temperature *) | °C | + 40 |
|
|
|
Min. storage / operating temperature **) | °C | + 5 |
|
|
|
Pressure vessel volume | l | 50 |
|
|
|
No. of air outlets |
| 1 |
|
|
|
No. of cylinders |
| 2 |
|
|
|
Anzugsmoment Zylinderkopfschraube | Nm | 9 |
|
|
|
Speed | 2900 | |
Motor capacity | kW | 1,8 |
|
|
|
Supply voltage (50 Hz) | V | 230 |
|
|
|
Rated current | A | 7.9 |
|
|
|
Fuse protection min. | A | 16 |
|
|
|
Degree of protection |
| IP44 |
|
|
|
Maximale Gesamtlänge bei Verwendung von Verlängerungskabeln: |
|
|
– bei 3 x 1,5 mm2 Aderquerschnitt | m | 10 |
– bei 3 x 2,5 mm2 Aderquerschnitt | m | 20 |
Required oil quantity (pump) | l | 0.45 |
|
|
|
Dimensions: length x width x height | mm | 770 x 500 x 700 |
|
|
|
Weight | kg | 45 |
|
|
|
Sound pressure level LPA at 1 m maximum | dB (A) | 89 ±3 |
Sound power level LWA | dB (A) | 97 |
All specifications refer to 20 °C ambient temperature.
*) The service life of certain components, e.g. the gasket in the check valve, is greatly reduced when operating the compressor at high temperatures (maximum storage/operating temperature and above).
**) At temperatures below the minimum storage/operating temperature there is a risk of the condensate freezing in the pressure vessel.
14