3.Remove the motor junction box cover (see Figure 8).

Motor

Junction Box

Figure 8. Motor location.

4.Rewire the motor per the diagram on the inside of the motor junction box, using the additional wiring nuts included with the 440V conversion kit.

Note: A wiring diagram is provided in the back of this manual for your reference; it is current at the time of printing, but the machine may change. The diagram on the inside of the motor junction box will always be current with the motor.

5.Remove the magnetic switch cover.

6.Replace the original magnetic switch assem- bly with the assembly included in the 440V conversion kit. Set the dial on the new over- load relay to 11A (Figure 9).

Magnetic

Contactor

Overload

Relay Dial

Overload

Relay

Figure 9. Magnetic switch.

7.

Reinstall the switch cover.

-14-

G0460/G0461 12" Sliding Table Saw

Image 16
Contents Sliding Table SAW Page Table of Contents Foreword IntroductionContact Info Machine Data Sheet G0460/G0461 12 Sliding Table Saw Identification Page Safety Safety Instructions for MachineryAlways Lock Mobile Bases if Used Before Operating Machinery Safety Instructions for Sliding Table Saws Protecting Yourself From Kickback Preventing KickbackTips to reduce the likelihood of kickback Glossary of Terms Circuit Requirements Rewiring to GroundingMagnetic switch Setup Setup Safety UnpackingItems Needed for Setup Description QtyClean Up Inventory Inventory QtyHardware and Tools Lock Washers 8mm Small Wing/TableHardware Recognition Chart Placement Site ConsiderationsMoving & Placing Base Unit Floor LoadMounting to Shop Floor Bolting to Concrete FloorsExtension Tables To install the extension tablesComponents and Hardware Needed Qty To install the blade Main BladeTo install the rip fence Rip Fence and ScalePage To install the riving knife Riving KnifeSet screws for adjusting riving knife To install the scoring blade Scoring BladeTo install the crosscut table Aligning BladesCrosscut Table To align the blades and riving knifeTo install the crosscut fence Crosscut FenceFence Scale Alignment To align the rip fence scale with the bladeTest Run Operation Safety OperationsOperation Tips Please follow these tips Every time you use your sawChanging Blades To change the bladesRip Cutting Rip cutting with the sliding tableRip cutting with the rip fence Crosscutting Crosscutting full size panels Crosscutting using the rip fence as a cut-off gaugeCrosscutting smaller panels Miter Cutting To perform a miter cutAccessories H3308-SHOP FOX Push StickG3445-Precision Saw Tool H3771-Blade LocH1300 H1298 G7984 H2347 H0736 H6460-12 Tooth Scoring Blade SetMaintenance CleaningSchedule Unpainted Cast IronLubrication See FigureService TroubleshootingSymptom Possible Cause Possible Solution Motor & ElectricalCutting Operations To change the main blade arbor V-belt Replacing BeltsTo change the scoring blade arbor flat belt Blade Tilt To calibrate the blade tiltSquaring Crosscut Fence to Blade To square the crosscut fence with the bladeTo adjust the sliding table parallel with the main blade Sliding Table ParallelismG0460 Electrical Components G0460 Wiring Diagram G0461 Electrical Components G0461 Wiring Diagram at G0461 Wiring Diagram at Parts Main BodyMain Body Parts List DescriptionPW01M Flat Washer 8MM Sliding Table Sliding Table Parts List Crosscut Table Crosscut Table Parts List Description Rip Fence Tilt Assembly Motor Assembly PK42MArbor Assembly Warranty and Returns Warranty Card CommentsGrizzly INDUSTRIAL, INC BOX BELLINGHAM, WA