PROBLEM | CAUSE | CORRECTION |
Motor will not | Motor overheated | Allow compressor to cool for |
run. |
| approximately 30 minutes so |
|
| thermal overload switch will |
|
| reset. If unit still does not |
|
| start, empty air from tank and |
|
| refer to "Thermal overload |
|
| protector cuts out |
|
| repeatedly" information. |
| Fuse blown, circuit breaker | Check fuse box for blown |
| tripped. | fuse and replace as |
|
| necessary. Reset circuit |
|
| breaker. Do not use a fuse or |
|
| circuit breaker with higher |
|
| rating than that specified for |
|
| your particular branch circuit. |
|
| Check for proper fuse. You |
|
| should use a time delay fuse. |
|
| Check for low voltage |
|
| problem. |
|
| Check the extension cord. |
|
| Disconnect the other |
|
| electrical appliances from |
|
| circuit or operate the |
|
| compressor on its own |
|
| branch circuit. |
| Extension cord is wrong | Check the extension cord. |
| length or gauge. |
|
| Faulty motor. | Have checked by a Trained |
|
| Service Technician. |
|
|
|
AIR COMPRESSOR REPAIR PARTS
For Parts, Service, Warranty or other Assistance, please call
17- ENG | A05581 |