Delta A05581 instruction manual Glossary, Specifications, Model No CP201

Page 8

GLOSSARY

Become familiar with these terms before operating the unit. CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure of air delivery.

PSIG: Pounds per square inch gauge; a unit of measure of pressure.

Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, CSA/US have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.

CSA: Electrical products sold in Canada are required to be certified to the applicable CSA standard (s). Canadian Standards Association (CSA) is a standards writing and safety testing organization. Products that are CSA certified have been evaluated and tested and found to meet or exceed the applicable CSA standard (s) for safety and electrical performance.

Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called “cut-in” pressure.

Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called “cut-out” pressure.

Branch Circuit: Circuit carrying electricity from electrical panel to outlet.

SPECIFICATIONS

Model No.

CP201

Voltage/Hertz/ Phase

120V/60/1

Minimum Branch Circuit Requirement

15 amps

*Fuse Type

Time Delay

Air Tank Capacity

2 Gallons

Approximate Cut-in Pressure

75 PSI

Approximate Cut-out Pressure

100 PSI

*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit on which the air compressor is operated. If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked “D” in Canada and “T” in the US.

A05581

8- ENG

Image 8
Contents Oil-Free Air Compressor Serious injury Result in property damage Safety Guidelines DefinitionsImportant Safety Instructions Hazard What Could HappenHOW to Prevent IT What can HappenHazard Belt can cause serious injury if they What can Happen HOW to Prevent ITNever operate the compressor with Hazard Model No CP201 SpecificationsGlossary Installation Grounding InstructionsVolt U.S.A. Plug Grounding PinExtension Cords Operation Auto/On/Off Switch Set switchPressure Switch not shown How to Use Your Unit How to StopMaintenance How to StartStorage Troubleshooting Problem Cause Correction AIR Compressor Repair Parts Limited Warranty Responsibility of Original Purchaser initial UserCompresor de Aire Sin Aceite Definiciones DE Normas DE Seguridad Importantes Instrucciones DE SeguridadResultar en lesiones menores o ModeradasInstrucciones Importantes DE Seguridad Guarde Estas InstruccionesAgregados Y Accesorios 23- SP A05581 Advertencia Riesgo DE Quemaduras ¿QUÉ Puede OCURRIR? Advertencia Riesgo DE Caida ¿QUÉ Puede OCURRIR?Advertencia Riesgo DE Operación Insegura ¿QUÉ Puede OCURRIR? Modelo Nº CP201 GlosarioEspecificaciones Instalación Cómo Preparar LA UnidadEnchufe de 120 V, EE.UU Uso localCables de extensión eléctrica Protección del voltaje y del circuitoDescripción de operaciones OperaciónConozca su compresor de aire Antes de cada puesta en marcha Cómo utilizar su unidad Cómo detenerlaAntes de poner en marcha Mantenimiento Cómo poner en marchaResponsabilidades del cliente Cómo verificar la válvula de seguridadAlmacenaje Aire, originando un riesgo de ruptura de sus paredesGuía DE Duagnóstico DE Problemas Problema Causa CorrecciónDesciende cuando Piezas DE Reparación El motor no funcionaGarantía Limitada AÑO Garantía limitada sobre todos los serviciosCompresseur dair sans huile Conserver CES Directives Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Avertissement Risque D’EXPLOSION OU D’INCENDIE PréventionAvertissement Risque DE Projection D’OBJETS Avertissement Risque D’ÉCLATEMENTRisque Avertissement Risque DE Choc Électrique Avertissement Risque PAR InhalationAvertissement Risque DE Chute Avertissement Risque DE BrûluresAvertissement Risque Relié AUX Pièces Mobiles Avertissement Risque Dune Utilisation Dangereuse Modèle N CP201 LexiqueSpécifications Emplacement du compresseur dair Montage DE LappareilRallonges Protection contre la surtension et protection du circuitDescription du fonctionnement UtilisationFamiliarisez-vous avec votre compresseur dair Utilisation de lappareil Avant le démarrageAvant chaque mise en marche Arrêt de lappareilEntretien Mise en marcheResponsabilités du client Vérification de la soupape de sûretéRangement Dépannage Peut éclater ou exploserD., pendant lutilisation dun Pièces DE Rechange Pas DéclenchéRemarque 55- FR A05581 AN Garantie limitée sur tous les accessoires Garantie Limitée