Bosch Power Tools GPL2 manual Equipment, Multiple-Purpose Attachment, Use and care

Page 4

!Changes or modifications to this unit not expressly approved by the party WARNING responsible for compliance could void the user’s authority to operate the

equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna.

-Increase the separation between the equipment and receiver.

-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

-Consult the dealer or an experienced radio/TV technician for help.

Work area safety

Keep work area clean and well lit. Cluttered or dark areas invite accidents.

DO NOT operate the laser tool around children or allow children to operate the laser tool. Serious eye injury could result.

Electrical safety

Batteries can explode or leak, cause injury or fire. To reduce this risk, always follow all instructions and warnings on the battery label and package.

DO NOT short any battery terminals. DO NOT charge alkaline batteries. DO NOT mix old and new batteries.

Replace all of them at the same time with new batteries of the same brand and type.

DO NOT mix battery chemistries.

Dispose of or recycle batteries per local code.

DO NOT dispose of batteries in fire. Keep batteries out of reach of children.

Remove batteries if the device will not be used for several months.

Personal safety

Stay alert, watch what you are doing and use common sense when operating a tool. Do not use a tool while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating a tool may result in serious personal injury or incorrect measurement results.

Use safety equipment. Always wear eye protection. Safety equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries.

Multiple-Purpose Attachment

Keep the multiple-purpose attachment 8 away from cardiac pacemakers. The magnets 12 generate a field that can impair the function of cardiac pacemakers.

Keep the multiple-purpose attachment 8 away from magnetic data medium and magnetically-sensitive equipment. The effect of the magnets 12 can lead to irreversible data loss.

Use and care

Use the correct tool for your application. The correct tool will do the job better and safer.

Do not use the tool if the switch does not turn it on and off. Any tool that cannot be controlled with the switch is dangerous and must be repaired.

Store idle tool out of the reach of children and do not allow persons unfamiliar with the tool or these instructions to operate the tool. Tools are dangerous in the hands of untrained users.

Maintain tools. Check for misalignment or binding of moving parts, breakage of parts and any other condition that may affect the operation. If damaged, tool must be repaired by the authorized Bosch service center before further use. Many accidents are caused by poorly maintained tools.

-4-

Image 4
Contents Service Locations De service après-vente, appelez Pour obtenir des informations Llame gratis paraObtener información Ce numéro gratuit Ubicaciones de servicioGPL Using the tool General Safety RulesFollowing labels are on your laser tool for Multiple-Purpose Attachment EquipmentUse and care Intended Use FeaturesPreparation Technical Data OperationWorking Advice Recalibration Procedure Up & Down BeamsLeveling Accuracy Influences on AccuracyCalibrating the Top and Bottom Beams Applications Use with AttachmentsWorking with the Measuring Plate Optional Accessory Maintenance and ServiceLaser Viewing Glasses Optional Accessory Limited Warranty of Bosch Laser and Measuring Tool Products Day Money Back Refund or ReplacementConsignes générales de sécurité Mise EN Garde et n’effacez pas desDe l’utilisateur de faire fonctionner l’équipement Sécurité sur le lieu de travailSécurité électrique NE Jetez PAS des piles dans un feuService après-vente Emploi prévuPréparation En plastiqueMise en service Données techniquesConsignes d’utilisation Réglage de la coupure automatiqueInfluences sur la précision Précision de nivellementContrôler la précision du nivellement Vertical Procédure d’Étalonnage Étalonnage des faisceaux laser du haut Et du basMise d’aplomb d’une surface Utiliser avec accessoriesTransfert de points ą l’aide du faisceau De mise d’aplomb Maintenance et service Travailler avec le trépied accessoireTravailler avec la platine de mesure Accessoire Lunettes de vision du faisceau laser AccessoireRemboursement ou remplacement du produit jusqu’à 30 jours Nomas generales de seguridad Declaración de FCCOperar el equipo Las lesiones corporalesBase multifuncional Seguridad eléctricaUso previsto PreparaciónCaracterísticas ServicioDatos Técnicos OperaciónPrecisión de nivelación En el momento en que dejen de moverse los puntos láserInstrucciones para la operación Factores que afectan a la precisiónContinuación Procedimiento de RecalibraciónCalibración de los haces superior e Inferior Aplicaciones Utilice con accesorios especialMantenimiento y servicio Gafas para láser accesorio especialPage Page