Lincoln Electric IM10018-A manual Installation, Technical Specifications Idealarc DC-600 VRD

Page 9

A-1

 

 

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS – IDEALARC® DC-600 VRD

 

 

 

 

 

 

 

 

 

 

 

INPUT - THREE PHASE ONLY

 

 

CODES

Standard

 

 

Input Current at Rated Output

 

 

Voltage

 

100% Duty Cycle

 

60% Duty Cycle

50% Duty Cycle

 

 

 

 

 

 

 

 

 

11613, 11707

230/460/575/60

 

108/54/43

 

122/61/49

134/67/54

 

11598, 11725

415/50/60

 

62

 

68

73

 

 

 

 

 

 

 

 

 

RATED OUTPUT

Duty Cycle

100% Duty Cycle

60% Duty Cycle

50% Duty Cycle

Output Range

70A/13V-780A/44V (CV) 90A/24V-780A/44V (CC)

Amps

600

680

750

OUTPUT

Maximum Open Circuit Voltage

5V for 60 HZ models

5V for 50/60 HZ models

Volts at Rated Amperes

44

44

44

Auxiliary Power

See the OPERATION section

for Auxiliary Power

information by model

RECOMMENDED INPUT WIRE AND FUSE SIzES

INPUT

HERTz

INPUT AMPERE

TYPE 75°C

TYPE 75°C

TYPE 75°C

COPPER WIRE

GROUND WIRE

(SUPER LAG)

VOLTAGE /

 

RATING ON

 

IN CONDUIT

IN CONDUIT

OR bREAKER

FREQUENCY

 

NAMEPLATE

 

AWG(IEC-MM2) SIzES

AWG(IEC-MM2) SIzES

SIzE (AMPS)1

 

 

 

 

 

 

30°C (86°F) Ambient

 

 

230

60

108

2 (34)

6 (14)

175 Amp

460

60

54

6 (14)

8 (8.4)

90 Amp

575

60

43

8 (8.4)

8 (8.4)

70 Amp

415

50/60

61

6 (14)

8 (8.4)

100 Amp

 

 

 

 

 

 

PHYSICAL DIMENSIONS

HEIGHT

WIDTH

DEPTH

WEIGHT

30.75 in

22.25 in

39.0 in

525 lbs.

781 mm

567 mm

988 mm

238 kg.

 

 

 

 

1Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of the current increases.

IDEALARC® DC-600 VRD

Image 9
Contents Idealarc DC-600 VRD Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSafety On-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTAbLE of Contents TAbLE of Contents Technical Specifications Idealarc DC-600 VRD InstallationSafety Precautions Stacking Hole Stacking PinsElectric Shock can Kill Select Proper LocationInput Power Supply Connections Fuse and Wire SIzESElectrical Input Connections Ground ConnectionSee Machine Rating Plate for Required Input Supply Voltage Reconnect ProcedureELECTRODE, Work and #21 Lead Connections Output ConnectionsNections Auxiliary Power and Control CONTerminal Strip 1 T.S.1 Terminal Strip 2 T.S.2Electric Shock can kill Fumes and Gases can be dangerousARC Rays can burn Operation Design Features and AdvantagesGeneral Description Recommended Processes and EQUIP- MentOFF Input Power Output Control Output Voltage CurrentOutput Terminals Input Power ON/OFF Switch Controls and SettingsPower Light NectionAuxiliary Power in MS-RECEP- Tacle For codes 11707 and above OVERLOAD, OVERCURRENT, and Fault ProtectionWelding Procedure Recommendations Remote Control of Machine OperationCV Mode CC ModeNA-3 Automatic Wire Feeder Operation Wire Feeders and Tractors AccessoriesField Installed Options Factory or Field Installed OptionsFigure C.2 MULTI-PROCESS Switch CAbLE Connections Accessories 1MAINTENANCED-1 Safety Precautions Electric Shock can KillRoutine and Periodic Maintenance TROUbLESHOOTING Static-Sensitive Board can be damaged by static electricityDevices Handle only atOutput PRObLEMS TROUbLESHOOTING LOCAL/REMOTE Switch TROUbLESHOOTING Check all Three-Phase input Facility PRObLEMS Symptoms Welding PRObLEMS Poor arc characteristics in all processes Control P.C. bOARD BOARD TROUbLESHOOTING GuideConnecting Remote Output Control Rheostat to the Machine Checking Power ON/OFF Switch S1BOARD TROUbLESHOOTING Guide VRD P.C. bOARD Checking Output Control RHEO- Stat on Machine R1Diagrams Diagrams Diagrams Diagrams Feeder Connection of LN-742 to the DC-600 VRD Power SourceConnection of LN-7 to the DC-600 VRD Power Source 600 Connection of LN-8 or LN-9 to the DC-600 VRD Power SourceControl Cable Connection of NA-5/-5R to the DC-600 VRD Power Source Lincoln Wire DC-600 VRD Dimension Print with K817P Undercarriage DC-600 VRD Dimension Print with K842 Undercarriage Precaucion Warnung