Lincoln Electric IM805 manual Installation, Safety Precautions, Location / Ventilation

Page 10

A-2

INSTALLATION

A-2

Read this entire installation section before you start installation.

SAFETY PRECAUTIONS

WARNING

Do not attempt to use this equipment until you have thoroughly read all operating and maintenance manuals supplied with your machine. They include important safety precautions, detailed engine starting, operating and maintenance instructions and parts lists.

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

Insulate yourself from the work and ground.

Always wear dry insulating gloves.

-------------------------------------------------------------------------------------

ENGINE EXHAUST can kill.

• Use in open, well ventilated areas or vent exhaust outside

-------------------------------------------------------------------------------------

MOVING PARTS can injure.

Do not operate with doors open or guards off.

Stop engine before servicing.

Keep away from moving parts

-------------------------------------------------------------------------------------

Only qualified personnel should install, use or service this equipment.

LOCATION / VENTILATION

The welder should be located to provide an unrestricted flow of clean, cool air to the cooling air inlets and to avoid restricting the cooling air outlets. Also, locate the welder so that the engine exhaust fumes are properly vented to an outside area.

CAUTION

DO NOT MOUNT OVER COMBUSTIBLE SURFACES

Where there is a combustible surface directly under stationary or fixed electrical equipment, that surface should be covered with a steel plate at least .06”(1.6mm) thick, which should extend not less than 5.90”(150mm) beyond the equipment on all sides.

STORING

1.Store the machine in a cool, dry place when it is not in use. Protect it from dust and dirt. Keep it where it can’t be accidentally damaged from construction activities, moving vehicles, and other hazards.

2.Drain the engine oil and refill with fresh 10W30 oil. Run the engine for about five minutes to circulate oil to all the parts. See the MAINTENANCE section of this manual for details on changing oil.

3.Remove the battery, recharge it, and adjust the electrolyte level. Store the battery in a dry, dark place.

STACKING

Vantage machines cannot be stacked.

ANGLE OF OPERATION

To achieve optimum engine performance the Vantage should be run in a level position. The maximum angle of operation for the Deutz engine is 30 degrees fore and aft, 40 degrees right and 45 degrees left. If the engine is to be operated at an angle, provisions must be made for checking and maintaining the oil level at the normal (FULL) oil capacity in the crankcase. When operating the welder at an angle, the effective fuel capacity will be slightly less than the specified 25 gallons.

Vantage 500 DEUTZ

Image 10
Contents Vantage 500 Deutz Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Vii Installation Safety Precautions InstallationLocation / Ventilation High Altitude Operation High Temperature OperationLifting TowingEngine Cooling System PRE-OPERATION Engine ServiceEngine BREAK-IN 5INSTALLATIONA-5 Welding TerminalsStandby Power Connections Remote ControlAuxiliary Power Receptacles OutputFigure A.2 Connection of the Vantage to Premises Wiring Connection of LN-7, LN-8 or LN-742 to the Vantage Connection of Lincoln Electric Wire FeedersConnection of AN LN-23P Wire Feeder to the Vantage Connection of LN-15 to the VantageConnection of the LN-25 to the Vantage Vantage 500 DeutzOperation Safety InstructionsGeneral Description Controls and Settings RUNWelding Controls Items 9 through Starting the Engine Auxiliary Power ControlsEngine Operation Stopping the EngineWelder Operation Operation For Tungsten ElectrodesAuxiliary Power Operation Operation Accessories Optional Field Installed AccessoriesRoutine and Periodic Maintenance MaintenanceEngine Maintenance Water Separator Element Fuel PRE-FILTER/WATER Separator AssemblyFuel Filters Secondary Fuel FilterBattery Handling Cooling System Cooling Blower BeltWelder / Generator Maintenance Troubleshooting HOW to USE Troubleshooting GuideMisadjustments Course of Action Possible AreasFunction Problems 500 DIAGRAMSF-2 Connection DiagramCommander / K867 / K775 / LN-7 Connection Diagram DiagramDiagrams Diagrams Commander / K867 / LN-8 Connection Diagram Diagrams Diagrams Engine Welders /LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Dimension Print Vantage 500 Deutz Mojada Insulate yourself from workGround Inflammable Votre corps Avec des pièces sous tensionHumos. Utilice ventilación o Servicio Aspiración para gases Keep your head out of fumes Turn power off before servicingGuards off Débranchez le courant avant Utilisez un ventilateur ou un