Lincoln Electric IM805 manual Connection of Lincoln Electric Wire Feeders

Page 16

A-8

INSTALLATION

A-8

CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS

WARNING

Shut off welder before making any electrical connections.

-------------------------------------------------------------------------------------

CONNECTION OF LN-7, LN-8 OR LN-742 TO THE VANTAGE

Shut the welder off.

Connect the LN-7, LN-8 or LN-742 per instructions on the appropriate connection diagram in the DIAGRAMS section.

Set the “WIRE FEEDER VOLTMETER” switch to either “+” or “- ” as required by the electrode being used.

Set the “SELECTOR” switch to the “CV-WIRE” position.

Adjust the “ARC CONTROL” knob to desired Crispness. SOFT for MIG and CRISP for INNERSHIELD.

Set the “WELDING TERMINALS” switch to the “REMOTELY CONTROLLED” position.

CONNECTION OF LN-15 TO THE VANTAGE

These connections instructions apply to both the LN-15 Across- The-Arc and Control Cable models. The LN-15 has an internal contactor and the electrode is not energized until the gun trigger is closed. When the gun trigger is closed the wire will begin to feed and the welding process is started.

Shut the welder off.

For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode Negative, connect the electrode cable "-" terminal of the welder and work cable to the "+" terminal of the welder.

Across-The-Arc Model:

Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

Control Cable Model:

Connect Control Cable between Engine Welder and Feeder.

Set the MODE switch to the "CV-WIRE " position.

Across-The-Arc Model:

Set the "WELD TERMINALS" switch to "WELD TERMINALS ON"

Control Cable Model:

Set the "WELD TERMINALS" switch to "REMOTELY CONTROLLED"

Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode polarity being used.

Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

CONNECTION OF AN LN-23P WIRE FEEDER TO THE VANTAGE

Shut the welder off.

Connect the LN-23P per instructions on the appropriate connection diagram in the DIAGRAMS section. (NOTE): When connecting an LN-23P to the Vantage , a K350-1 adapter kit must be used.

Set the “WIRE FEEDER VOLTMETER” switch to “-”.

Set the “SELECTOR” switch to “CV-WIRE” position.

Set the “WELDING TERMINALS” switch to “REMOTELY CONTROLLED”.

Set the ARC CONTROL to desired crispness.

If you are using an LN-23P with the K350-1 adapter kit, the electrode is not energized until the gun trigger is closed.

Vantage 500 DEUTZ

Image 16
Contents Vantage 500 Deutz Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Vii Installation Safety Precautions InstallationLocation / Ventilation High Temperature Operation LiftingHigh Altitude Operation TowingEngine Cooling System PRE-OPERATION Engine ServiceEngine BREAK-IN 5INSTALLATIONA-5 Welding TerminalsRemote Control Auxiliary Power ReceptaclesStandby Power Connections OutputFigure A.2 Connection of the Vantage to Premises Wiring Connection of Lincoln Electric Wire Feeders Connection of AN LN-23P Wire Feeder to the VantageConnection of LN-7, LN-8 or LN-742 to the Vantage Connection of LN-15 to the VantageConnection of the LN-25 to the Vantage Vantage 500 DeutzOperation Safety InstructionsGeneral Description Controls and Settings RUNWelding Controls Items 9 through Auxiliary Power Controls Engine OperationStarting the Engine Stopping the EngineWelder Operation Operation For Tungsten ElectrodesAuxiliary Power Operation Operation Accessories Optional Field Installed AccessoriesRoutine and Periodic Maintenance MaintenanceEngine Maintenance Fuel PRE-FILTER/WATER Separator Assembly Fuel FiltersWater Separator Element Secondary Fuel FilterBattery Handling Cooling System Cooling Blower BeltWelder / Generator Maintenance Troubleshooting HOW to USE Troubleshooting GuideMisadjustments Course of Action Possible AreasFunction Problems 500 DIAGRAMSF-2 Connection DiagramCommander / K867 / K775 / LN-7 Connection Diagram DiagramDiagrams Diagrams Commander / K867 / LN-8 Connection Diagram Diagrams Diagrams Engine Welders /LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Dimension Print Vantage 500 Deutz Insulate yourself from work GroundMojada Inflammable Votre corps Avec des pièces sous tensionKeep your head out of fumes Turn power off before servicing Guards offHumos. Utilice ventilación o Servicio Aspiración para gases Débranchez le courant avant Utilisez un ventilateur ou un