Lincoln Electric IM805 manual Installation

Page 9

A-1

 

 

 

INSTALLATION

 

 

A-1

TECHNICAL SPECIFICATIONS - Vantage 500 DEUTZ (K2271-1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - DIESEL ENGINE

 

 

 

Make /Model

Description

Speed (RPM)

Displacement

 

Starting

Capacities

 

 

 

 

 

 

 

 

 

System

 

Deutz

3 cylinder

High Idle 1900

173 cu. in

12VDC battery

Fuel

F3L 912

44HP (33 kw)

 

 

(2.83L)

 

& Starter

(25 US gal)

Diesel Engine

@ 1800 RPM

Full Load 1800

 

 

 

 

94.6L

 

 

 

 

 

 

Bore x Stroke

 

 

Oil:

 

 

 

 

 

 

 

 

 

 

9.5 QTS.

 

 

 

 

 

 

3.94” x 4.72”

 

 

9.0L

 

 

 

 

 

 

(100mm x 120mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT @ 104°F(40°C) - WELDER

 

Duty Cycle

 

 

 

Welding Output

 

 

Volts at Rated Amps

100%

 

 

 

500 Amps (DC multi-purpose)

 

40 Volts

 

60%

 

 

 

550 Amps (DC multi-purpose)

 

36 volts

 

50%

 

 

 

575 Amps (DC multi-purpose)

 

35 volts

 

 

 

 

 

 

 

 

 

 

OUTPUT @ 104°F(40°C) - WELDER AND GENERATOR

 

 

 

 

 

Welding Range

 

 

 

 

 

 

 

30 - 575 Amps CC/CV

 

 

 

 

 

 

 

20 - 250 Amps TIG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open Circuit Voltage

 

 

 

 

 

 

 

60 Max OCV @ 1900 RPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary Power (1)

 

 

 

 

 

 

 

120/240 VAC

 

 

 

 

 

 

 

12,000 WATTS, 60 Hz.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

Height (2)

 

 

Width

 

Depth

 

Weight

42.0 in

 

 

31.5 in.

 

63.1 in.

 

1615 lbs.

(1066.8 mm)

 

 

(800.1mm)

 

(1603mm)

 

(733kg)

 

 

 

 

 

 

 

 

 

(Approx)

1.Output rating in watts is equivalent to volt-amperes at unity power factor.

Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2.Top of Enclosure. Add 6.6” (167.6mm) for exhaust.

Vantage 500 DEUTZ

Image 9
Contents Vantage 500 Deutz California Proposition 65 Warnings SafetyElectric Shock can kill Welding Sparks can cause fire or explosion Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Vii Installation Installation Safety PrecautionsLocation / Ventilation Lifting High Temperature OperationHigh Altitude Operation TowingPRE-OPERATION Engine Service Engine Cooling SystemEngine BREAK-IN Welding Terminals 5INSTALLATIONA-5Auxiliary Power Receptacles Remote ControlStandby Power Connections OutputFigure A.2 Connection of the Vantage to Premises Wiring Connection of AN LN-23P Wire Feeder to the Vantage Connection of Lincoln Electric Wire FeedersConnection of LN-7, LN-8 or LN-742 to the Vantage Connection of LN-15 to the VantageVantage 500 Deutz Connection of the LN-25 to the VantageSafety Instructions OperationGeneral Description RUN Controls and SettingsWelding Controls Items 9 through Engine Operation Auxiliary Power ControlsStarting the Engine Stopping the EngineWelder Operation For Tungsten Electrodes OperationAuxiliary Power Operation Operation Optional Field Installed Accessories AccessoriesMaintenance Routine and Periodic MaintenanceEngine Maintenance Fuel Filters Fuel PRE-FILTER/WATER Separator AssemblyWater Separator Element Secondary Fuel FilterCooling System Cooling Blower Belt Battery HandlingWelder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingPossible Areas Misadjustments Course of ActionFunction Problems 500 Connection Diagram DIAGRAMSF-2Diagram Commander / K867 / K775 / LN-7 Connection DiagramDiagrams Diagrams Commander / K867 / LN-8 Connection Diagram Diagrams Diagrams Engine Welders /LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Dimension Print Vantage 500 Deutz Ground Insulate yourself from workMojada Inflammable Votre corps Avec des pièces sous tensionGuards off Keep your head out of fumes Turn power off before servicingHumos. Utilice ventilación o Servicio Aspiración para gases Débranchez le courant avant Utilisez un ventilateur ou un