Teledyne instruction manual Recommended Spare Parts List, Model 9700 System Standard Unit Only

Page 47

 

 

Flue Gas Analysis System

Appendix

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recommended Spare Parts List

Model 9700 System

(Standard Unit Only)

PART NO.

 

DESCRIPTION

QTY

F-77

Fuse, Tvpe 3AG, 6-1/4A, Slo-Blo

5

S-81

Triac, G. E. #SC45B

1

T-199

Thermoswitch, Fenwall #32410-2 (130 deg F)

1

T-267

Thermoswitch, H-B #7920A (85 deg F)

1

H-2

Heater, Vulcan #1208

1

H-28

Heater, Chromalox #A-00, 125 W

1

N-49

Nozzle, Spray, Spraying Systems #1/8 GD 3.5

1

C-11577

Control Unit, Combustible Analyzer

1

F-6.

• Fuse, Type 3AG, 1/4A, Slo-Blo

5

R-179

• Relay (K2), P.B. #KHP 17D11-24V

1

T-231

Transistor (Q1)

1

P-122

Potentiometer (P5)

1

R-564

•Regulator, Voltage (VR2)

1

A-38

•Amplifier, Operational (A1, A3)

2

A-9348

P.C. Board Assy, Oxygen Analyzer

1

A-19

Amplifier (A1, A2)

2

T-261

• Transistor, Field Effect (FET)(Q1)

1

S-89

Diode (D1-D4)

4

P-l00

• Potentiometer (R7, R8, R11)

3

B-12115

Sensor Probe Assy, Comb.

1

P-146

Pump, Flex-I-Liner, Vanton #18 Nordel

1

C-6689

Cell Assy, oxygen, A-3

1

F-96

Filter Element, MP #lO3-3PE

1

G-26

Gasket (for separator)

1

L-32

Lamp, G. E. #327 (Comb. Control Unit)

2

A-6544

Pin, Cell Contact (O2)

2

A-7023

Spring, Cell Contact

2

*For spare parts used with optional configurations, see any addenda attached to this manual.

Important: Orders for spare parts should include the part number, and the model and serial number of the system for which the part(s) is intended.

TELEDYNE BROWN ENGINEERING

A-3

Analytical Instruments

Image 47
Contents Model Flue Gas Analysis System Important Notice WarrantyTable of Contents Maintenance & Troubleshooting Overview Flue Gas Analysis SystemIntroduction Sample Conditioning General InformationSample Conditioning Oxygen Analyzer Section Standard FeaturesOxygen Analyzer Section General Information Optional Features General Information Combustible Gas Analyzer Section Combustible Gas Analyzer SectionGeneral Information Compound LEL Response Factor Operating Controls and Indicators Analog Output Recessed Secondary ControlsMeter Trim Current MAX Load Output Impedance Oxygen Analyzer Theory of OperationTheory of Operation Combustible Analyzer Detector Flue Gas Analysis System Theory of Operation Electrical Connections InstallationPower Output Signal VoltageInterconnection Diagram Output Signal Current Alarm and/or Control CircuitryInstallation Meter Zeroing OperationStartup of Oxygen Analyzer PreliminaryInitial Calibration and Equilibration Flue Gas Analysis System Operational Calibration Startup of Combustibles Analyzer ProcedureRoutine Operational Calibration Operation Sample System Startup Span GasSystem Startup Analyzer StartupOperation Oxygen Cell Replacement Flue Gas Analysis System Maintenance & TroubleshootingMaintenance Routine MaintenanceCell Warranty Combustible Sensor Spray NozzleWater Strainer Filter Condensate TrapGeneral TroubleshootingPump Oxygen Analyzer .2.2.1 Inability to Calibrate Inability to Calibrate Combustible Analyzer SectionNo Alarm With High Gas Level Lamp Failure Appendix SpecificationsOxygen Analysis Section Appendix ModelModel 9700 System Standard Unit Only Recommended Spare Parts ListReference Drawings Response of Combustible Sensor to Various Gases Appendix Model Supporting Equipment for Flue Gas Analysis Systems Figure A-1 Typical Dry Probe Repair General Maintenance for CC-2B Series PumpsMaintenance Appendix Model Flue Gas Analysis System Figure A-3 Pump Assembly Flue Gas Analysis System Figure A-4 Replacing Flex-I-Liner Replacing the Liner in the Flex-I-Liner PumpFlue Gas Analysis System