Teledyne 9700 instruction manual Figure A-3 Pump Assembly

Page 56

Appendix

Model 9700

 

 

 

 

NO.QTY DESCRIPTION

PART NO.

30

1

Support Bracket

8-86-051

29

1

Handle (opt)

 

28

4

5/16 x 5/8 Dowel Pin

 

27

1

1/4hp 1725rpm Motor

8-24-103

26

1

Shaft

 

25

1

Alemite Hydr. Fitting

1729

24

3

Shims

8-66-061

23

1

Bearing Guard

XB-45

22

1

Bearing Guard Spacer

8-70-030

21

2

Hose Adaptors

8-75

20

1

Rotor Bearing

HD-77600

19

1

Rotor

8-15

18

1

Retaining Ring

5100-39W

17

1

Expansion Ring

8-30

16

1

Pipe Plug 1/2" NPT

 

15

1

Silicone Oil Cup

XB-25

14

4

Hex Head Cap Screw

 

13

4

SAE Flat Washer

 

12

4

Soc Hd Cap Screw

 

11

4

Shake Proof Washers

 

10

1

Set Screw

 

9

1

Coupling

8-23-030

8

1

Groove Pin

 

7

1

Bracket

8-07

6

1

Bearing Spacer

8-50-032

5

2

Outboard Bearing

HD-29502

4

1

Flex-I-Liner

8-40-030

3

1

Retaining Ring

5000-37W

2

1

Body Block

8-25-030

1

1

Cover Plate

8-25-030

Pump Model

F

H-Tap

S2, S6, S12, S18

3/4

1/2-14 NPT

P2, P6, P12, P18

3/4

1/2-14 NPT

PY2, PY6, PY12, PY18

3/4

1/2-14 NPT

B2, B6, B12, B18

3/4

1/2-14 NPT

T2, T6, T12, T18

3/4

1/2-14 NPT

S90

1

3/4-14 NPT

P30, PY30, B30, T30

1

3/4-14 NPT

Figure A-3: Pump Assembly

A-12

TELEDYNE BROWN ENGINEERING

Analytical Instruments

Image 56
Contents Model Flue Gas Analysis System Warranty Important NoticeTable of Contents Maintenance & Troubleshooting Overview Flue Gas Analysis SystemIntroduction General Information Sample ConditioningSample Conditioning Standard Features Oxygen Analyzer SectionOxygen Analyzer Section General Information Optional Features General Information Combustible Gas Analyzer Section Combustible Gas Analyzer SectionGeneral Information Compound LEL Response Factor Operating Controls and Indicators Analog Output Recessed Secondary ControlsMeter Trim Current MAX Load Output Impedance Theory of Operation Oxygen AnalyzerTheory of Operation Combustible Analyzer Detector Flue Gas Analysis System Theory of Operation Installation PowerOutput Signal Voltage Electrical ConnectionsInterconnection Diagram Alarm and/or Control Circuitry Output Signal CurrentInstallation Operation Startup of Oxygen AnalyzerPreliminary Meter ZeroingInitial Calibration and Equilibration Flue Gas Analysis System Operational Calibration Startup of Combustibles Analyzer ProcedureRoutine Operational Calibration Operation Span Gas System StartupAnalyzer Startup Sample System StartupOperation Flue Gas Analysis System Maintenance & Troubleshooting MaintenanceRoutine Maintenance Oxygen Cell ReplacementCell Warranty Spray Nozzle Water StrainerFilter Condensate Trap Combustible SensorGeneral TroubleshootingPump Oxygen Analyzer .2.2.1 Inability to Calibrate Combustible Analyzer Section Inability to CalibrateNo Alarm With High Gas Level Lamp Failure Specifications AppendixAppendix Model Oxygen Analysis SectionRecommended Spare Parts List Model 9700 System Standard Unit OnlyReference Drawings Response of Combustible Sensor to Various Gases Appendix Model Supporting Equipment for Flue Gas Analysis Systems Figure A-1 Typical Dry Probe Repair General Maintenance for CC-2B Series PumpsMaintenance Appendix Model Flue Gas Analysis System Figure A-3 Pump Assembly Flue Gas Analysis System Replacing the Liner in the Flex-I-Liner Pump Figure A-4 Replacing Flex-I-LinerFlue Gas Analysis System