Teledyne 9700 instruction manual Table of Contents

Page 3

Flue Gas Analysis System

Table of Contents

1

Introduction

 

 

1.1

General

1

 

1.2

Sample Conditioning

2

 

1.3

Oxygen Analyzer Section

4

 

 

1.3.1

Standard Features

1-4

 

 

1.3.2

Optional Features

7

 

1.4

Combustible Gas Analyzer Section

9

 

 

1.4.1 Operating Controls and Indicators

12

 

 

1.4.2

Recessed Secondary Controls

13

 

 

1.4.3

Meter Trim

13

 

 

1.4.4

Analog Output

13

2

Theory of Operation

 

 

2.1

Oxygen Analyzer

1

 

2.2

Combustible Analyzer

3

 

2.3

Detector

4

3

Installation

 

 

3.1

Electrical Connections

1

 

 

3.1.1

Power

1

 

 

3.1.2

Output Signal Voltage

1

 

 

3.1.3 Alarm and/or Control Circuitry

3

 

 

3.1.4

Output Signal Current

3

4

Operation

 

 

4.1

Startup of Oxygen Analyzer

1

 

 

4.1.1

Preliminary

1

 

 

4.1.2

Meter Zeroing

1

 

 

4.1.4 Initial Calibration and Equilibration

2

 

 

4.1.5

Operational Calibration

4

 

 

4.1.6

Routine Operational Calibration

5

 

4.2

Startup of Combustibles Analyzer

5

 

 

4.2.1

Procedure

5

 

 

4.2.2

Span Gas

7

 

 

 

 

 

 

 

 

TELEDYNE BROWN ENGINEERING

i i i

Analytical Instruments

Image 3
Contents Model Flue Gas Analysis System Important Notice WarrantyTable of Contents Maintenance & Troubleshooting Flue Gas Analysis System IntroductionOverview Sample Conditioning General InformationSample Conditioning Oxygen Analyzer Section Standard FeaturesOxygen Analyzer Section General Information Optional Features General Information Combustible Gas Analyzer Section Combustible Gas Analyzer SectionGeneral Information Compound LEL Response Factor Operating Controls and Indicators Recessed Secondary Controls Meter TrimAnalog Output Current MAX Load Output Impedance Oxygen Analyzer Theory of OperationTheory of Operation Combustible Analyzer Detector Flue Gas Analysis System Theory of Operation Electrical Connections InstallationPower Output Signal VoltageInterconnection Diagram Output Signal Current Alarm and/or Control CircuitryInstallation Meter Zeroing OperationStartup of Oxygen Analyzer PreliminaryInitial Calibration and Equilibration Flue Gas Analysis System Operational Calibration Procedure Routine Operational CalibrationStartup of Combustibles Analyzer Operation Sample System Startup Span GasSystem Startup Analyzer StartupOperation Oxygen Cell Replacement Flue Gas Analysis System Maintenance & TroubleshootingMaintenance Routine MaintenanceCell Warranty Combustible Sensor Spray NozzleWater Strainer Filter Condensate TrapTroubleshooting PumpGeneral Oxygen Analyzer .2.2.1 Inability to Calibrate Inability to Calibrate Combustible Analyzer SectionNo Alarm With High Gas Level Lamp Failure Appendix SpecificationsOxygen Analysis Section Appendix ModelModel 9700 System Standard Unit Only Recommended Spare Parts ListReference Drawings Response of Combustible Sensor to Various Gases Appendix Model Supporting Equipment for Flue Gas Analysis Systems Figure A-1 Typical Dry Probe General Maintenance for CC-2B Series Pumps MaintenanceRepair Appendix Model Flue Gas Analysis System Figure A-3 Pump Assembly Flue Gas Analysis System Figure A-4 Replacing Flex-I-Liner Replacing the Liner in the Flex-I-Liner PumpFlue Gas Analysis System