6-3. Removing Contact Tip Adapter In XR-Edge Guns
1Nozzle
2Adapter Nozzle
3Nozzle Adapter Locking Nut
| 8 | Loosen locking nut to remove |
| nozzle and adapter nozzle. | |
7 |
| |
| 4 Contact Tip | |
|
|
2
1
6
5
4
3
5Collet Nut
6Quick Change Contact Tip Adapter
Remove contact tip from contact tip adapter.
7Insulated Sleeve
8Head Tube
Install insulated sleeve, then install and tighten new adapter into head tube. Reinstall contact tip, collet nut, adapter nozzle, and nozzle.
Tools Needed:
1/2 in
Ref. 802 253
6-4. Replacing Head Tube Liner In XR-Edge Guns
4
3
2
1
Insert chamfered end of liner into head tube.
.Turn OFF coolant supply before removing head tube on
Head tube liner is available for the following wire size ranges:
.030-.035 wire size
When changing wire size, change control box drive roll and idler (see Section
1Head Tube
2Head Tube Nut
Loosen head tube nut and remove head tube from gun.
3
4Liner
Pull liner out of head tube. Be sure
Insert new liner into head tube and reinstall head tube onto gun.
.Be sure head tube nut is securely tightened before operating gun. If head tube nut is not adequately tightened, un- wanted arcing may occur be- tween head tube and gun hous- ing.
Ref. 802 328