Carrier 40RMQ, 40RMS Ð High-Static Drive Data, 60 Hz Ð SI, Ð Standard Drive Data, 50 Hz Ð SI

Page 32

Table 9I Ð High-Static Drive Data, 60 Hz Ð SI

 

 

40RM

 

40RM

40RM

 

 

40RM

 

40RM

40RM

40RM

 

40RM

40RMQ

40RMS

40RMQ

 

40RMQ

 

UNIT

40RMS

 

 

40RMS

40RMS

40RMS

007

40RMS

010

40RMS

 

40RMS

 

 

014

 

 

024

028

034

 

 

008

 

012

 

 

016

 

 

 

 

 

 

 

 

 

 

 

MOTOR DRIVE

 

 

 

 

 

 

 

 

 

 

 

 

Motor Pulley Pitch Diameter

86.4-

86.4-

86.4-

86.4-

94.0-

 

 

109.2

 

109.2-

109.2-

109.2-

(mm)

111.8

111.8

111.8

111.8

119.4

 

 

134.6

 

134.6

134.6

134.6

Pulley Factory Setting

2.5

2.5

2.5

2.5

3.0

 

 

3.0

 

3.0

3.0

3.0

Full Turns Open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN DRIVE

 

 

 

 

 

 

 

 

 

 

 

 

Pulley Pitch Dia (mm)

178

152*

152

152

188

 

 

201

 

188

203

203

Pulley Bore (mm)

25.4

25.4

25.4

25.4

36.5

 

 

36.5

 

36.5

49.2

49.2

Belt No. Ð Section

1ÐA

1ÐA

1ÐA

1ÐA

1ÐB

1ÐB

2ÐB

2ÐB

2ÐB

 

Belt Pitch (mm)

1049

947

947

947

1011

 

 

1011

 

935

935

960

FAN SPEEDS (r/s)

 

 

 

 

 

 

 

 

 

 

 

 

Factory Setting

16.0

18.7

18.7

18.7

16.3

 

 

17.7

 

18.6

17.1

17.1

Range

14.0-

16.3-

16.3-

16.3-

14.4-

 

 

15.8-

 

16.9-

14.6-

14.6-

18.1

20.0*²

20.0²

20.0²

18.3

 

 

19.5

 

20.0²

17.9

17.9

 

 

 

 

Max Allowable Speed (r/s)

20.0

20.0

20.0

20.0

20.0

 

 

20.0

 

20.0

18.3

18.3

Change per 1¤2 Turn of

 

 

 

 

 

 

 

 

 

 

 

 

Moveable Motor Pulley

0.410

0.478

0.478

0.478

0.323

 

 

0.307

 

0.323

0.278

0.278

Flange

 

 

 

 

 

 

 

 

 

 

 

 

MAX FULL TURNS FROM

5

5

5

5

6

 

 

6

 

6

6

6

CLOSED POSITION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHAFTS CENTER DISTANCE

265-313

265-313

265-313

265-313

265-313**

 

232-279

 

207-255

169-240

169-240

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Values for 3-phase motor shown. For single-phase motor, pulley pitch diameter is 178 mm and resulting fan speed is 14.0-18.3 r/s.

²It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed 20 r/s.

**575-v unit has a center distance of 233-279.

Table 9J Ð Standard Drive Data, 50 Hz Ð SI

 

 

40RM

 

40RM

 

40RM

 

 

40RM

 

40RM

 

40RM

40RM

 

40RM

40RMQ

40RMS

40RMQ

 

 

40RMQ

 

 

UNIT

 

40RMS

 

 

40RMS

 

40RMS

40RMS

007

40RMS

010

40RMS

 

 

40RMS

 

 

 

 

014

 

 

024

 

028

034

 

 

008

 

012

 

 

 

016

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR DRIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor Pulley Pitch Diameter

61.0-

71.1-

71.1-

86.4-

 

86.4-

 

 

86.4-

 

109.2-

 

109.2-

109.2-

(mm)

86.4

96.5

96.5

111.8

 

111.8

 

 

111.8

 

134.6

 

134.6

134.6

Pulley Factory Setting

2.5

2.5

2.5

2.5

 

2.5

 

 

2.5

 

3.0

 

3.0

3.0

Full Turns Open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN DRIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pulley Pitch Dia (mm)

203

203

203

203

 

229

 

 

229

 

218

 

279

279

Pulley Bore (mm)

25.4

25.4

25.4

25.4

 

36.5

 

 

36.5

 

36.5

 

49.2

49.2

Belt No. Ð Section

1ÐA

1ÐA

1ÐA

1ÐA

 

1ÐA

1ÐA

1ÐB

2ÐB

 

2ÐB

 

Belt Pitch (mm)

998

998

998

1024

 

1074

 

 

1074

 

1062

 

1113

1113

FAN SPEEDS (r/s)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Setting

8.6

9.8

9.8

11.6

 

10.3

 

 

10.3

 

13.3

 

10.4

10.4

Range

7.1-

8.3-

8.3-

10.1-

 

9.0-

 

 

9.0-

 

11.9-

 

9.3-

9.3-

10.1

11.3

11.3

13.1

 

11.6

 

 

11.6

 

14.6

 

11.5

11.5

 

 

 

 

 

 

Max Allowable Speed (r/s)

20.0

20.0

20.0

20.0

 

20.0

 

 

20.0

 

20.0

 

18.3

18.3

Change per 1¤2 Turn of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Moveable Motor Pulley

0.297

0.297

0.297

0.297

 

0.265

 

 

0.265

 

0.230

 

0.180

0.180

Flange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAX FULL TURNS FROM

5

5

5

5

 

5

 

 

5

 

6

 

6

6

CLOSED POSITION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHAFTS CENTER DISTANCE

265-313

265-313

265-313

265-313

 

265-313

 

265-313

 

232-279

 

169-240

169-240

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

Image 32
Contents Installation, Start-Up Service Instructions Ð 40RM Physical Data, English Ð 40RMQ Physical Data, English Unit 40RMQChilled Water Coil Ð 40RMS Physical Data, EnglishUnit 40RMS Ð 40RM Physical Data, SI Ð 40RMQ Physical Data, SI Ð 40RMS Physical Data, SI Ð Dimensions Ð Sizes Unit Unit Weight40RM014 Ð Dimensions Ð Sizes 028,034 Unit 40RMQ 40RMSRefrigerant and Chilled Water Piping Access Holes NumbersFace-Split Coil Suction Liquid Line Piping Typical Liquid Unit Line Quantity 38AQS Size Required Reference Factory-Installed Nozzle and Distributor DataTXV Distributor Feeder Tubes Nozzle Unit PER Distributor Fitting Requirements 40RMQ11¤8 Street Elbow Nipple, 23¤4 L Long Radius Elbow Liquid Typical 40RMS Chilled Water Piping Condensate Drains Wiring and Service Access Side Panel Removed Voltage FAN Motor Power Supply Unit PH-HZ Electrical Data, Standard MotorsFLA MocpMocp Ð Electrical Data, Alternate MotorsFLA Ð Fan Contactor Coil Data Lubricant Data Manufacturer LubricantFan Shaft Bearing Fan Pulley Alignment Ð Align as follows Ð Fan Motor Data, Standard Motor Ð English Ð Fan Motor Data, Alternate Motor Ð English40RMQ 40RMS Unit 40RMS 40RMQ UnitÐ Fan Motor Data, Standard Motor Ð SI Ð Fan Motor Data, Alternate Motor Ð SIÐ Standard Drive Data, 60 Hz Ð English Ð Medium-Static Drive Data, 60 Hz Ð EnglishMotor Drive FAN DriveÐ High-Static Drive Data, 60 Hz Ð English Ð Standard Drive Data, 50 Hz Ð EnglishÐ Medium-Static Drive Data, 50 Hz Ð English Ð High-Static Drive Data, 50 Hz Ð English40RMQ Unit Ð Standard Drive Data, 60 Hz Ð SIÐ Medium-Static Drive Data, 60 Hz Ð SI Ð High-Static Drive Data, 60 Hz Ð SI Ð Standard Drive Data, 50 Hz Ð SIÐ Medium-Static Drive Data, 50 Hz Ð SI Ð High-Static Drive Data, 50 Hz Ð SIÐ Fan Performance Data Ð 0.0-1.2 in. wg ESP Ð English AirflowÐ Fan Performance Data Ð 1.4-2.4 in. wg ESP Ð English Unit Airflow Pressure Drop Ð Fan Performance Data Ð 0-300 Pa ESP Ð SI Ð Fan Performance Data Ð 350-600 Pa ESP Ð SI Filter Removal/Replacement Page Page Copyright 1995 Carrier Corporation START-UP Checklist Check Voltage Imbalance Comp A1 Comp B1