Graco Inc 244582, 309293K, 244581 Typical Installation PRO Xs Waterborne System Key

Page 10

Installation

 

 

B*

 

 

BB

 

Gun ES ON/OFF valve: I is ON, 0 is OFF

 

 

 

 

Q*

M

A

C

D E U

S

 

 

 

 

 

B*

 

 

P*

K*

L

 

 

 

 

 

AA

 

 

 

 

X

 

 

 

 

 

 

 

N

 

G

 

 

 

R

TI1896C

 

 

W

 

 

 

 

 

 

J

V*

 

 

 

 

 

 

 

Y

 

F

 

 

Z

T

 

 

 

 

 

 

H

 

TI1775C

Fig. 2. Typical Installation: PRO Xs Waterborne System

Key

A

Main Air Supply Line

B*

Main Air Supply Shutoff Valve (bleed-type)

CPump Air Pressure Gauge

DPump Air Pressure Regulator

EkV Meter

FPump

GPump Suction Hose

HPaint Container

J

Bleed Resistor

K*

Enclosure Safety Interlock

LIsolated Enclosure

MGun Air Line Filter

NGun Air Pressure Regulator

P*

Graco Red Grounded Air Supply Hose

Q*

Air Hose Ground Wire

RGraco Waterborne Fluid Hose

SWaterborne Electrostatic Air Spray Gun

TGrounding Rod

UGround Terminal

V*

Main Ground Wire

WStrain Relief/Ground Fitting

XPump Air Supply Line

YGrounding Cylinder

ZPump Fluid Outlet Fitting

AAIsolated Enclosure Door

BBEnclosure T-Handle Locking Screw

*Required for safe operation. Must be purchased separately.

10

309293K

Image 10
Contents Instructions/Parts List Table of Contents EN 50059 Compliant List of ModelsFM Approved Gun Model DescriptionSymbols Electric Shock HazardFire and Explosion Hazard Toxic Fluid HazardEquipment Misuse Hazard Pressurized Equipment HazardHow the Electrostatic Air Spray Gun Works IntroductionSpraying Waterborne Fluids Electrostatically Gun Overview Gun OverviewSystem Requirements Install the System InstallationFire, Explosion, and Electric Shock Hazard Typical Installation PRO Xs Waterborne System Key Ground the Cabinet Ventilate the Spray BoothConnect the Air Line Connect the Waterborne Fluid HoseShielded Hose Unshielded HoseWaterborne Hose Dimensions At Graco WB100 Enclosure Unshielded fluid connectionAgitator Kit Agitator KitFluid Regulator Kit Fluid Regulator KitFluid Nozzles Select a Fluid Nozzle and Air CapAir Caps Grounding Check Electrical Grounding Check Gun GroundingRelief Procedure on Operating ChecklistOperation Turn off the main air supply valve B Fill the Fluid Supply Adjust the Spray PatternFire and Explosion Hazard Fully open the fluid adjustment valve Air Regulator Settings Air Hose Length Air Regulator Setting Ft m Psi MPa, barWhen you finish spraying, perform the Shutdown procedure on Low Voltage Adjustment Low Voltage Adjustment Smart Guns OnlyShutdown Maintenance Flush the Spray GunDaily Care and Cleaning Do not immerse the gun in fluidMaintenance Grease Door Latch Threads Clean the Air Cap and Fluid NozzleProcedure Equipment NeededElectrical Tests Test Gun ResistanceTest Power Supply Resistance Test Power Supply ResistanceTest Electrode Resistance ElectrodeTest Ground Strip Resistance Test Cylinder ResistanceSpray Gun TroubleshootingVoltage Loss Troubleshooting Waterborne Fluid HoseVisual Check TestsTroubleshooting Spray Pattern Troubleshooting Gun Operation Troubleshooting Lowing the Fluid Voltage Discharge Grounding Procedure Electrical TroubleshootingSee Test Gun Resistance on See Check Electrical Grounding on 18 and Test Gun ResistancePrepare the Gun for Service RepairAir Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Repair Packing RodBarrel Installation Barrel RemovalPower Supply Removal and Replacement Power SupplyTurbine Alternator Removal and Replacement Fan Air Adjustment Valve Repair Fan Air Adjustment ValveFluid Adjustment Valve Repair Air Valve RepairAtomizing Air Restrictor Valve Removal and Replacement ES ON/OFF Valve RepairParts Ref. No Alternator 19a 19b Description Qty Hook 51 Ref 19a TI1487A Ti1601a Description Qty SWITCH, ES HI/LO TI2138a Plate DescriptionQty Tubing and Wiring Chart Code Length Description In. mmDetail of Door Interlock Switch Tubing and Wiring DiagramsDetail of Control Box Air Line Accessories AccessoriesFluid Line Accessories Gun Accessories Miscellaneous AccessoriesPart No Agitator Accessory Kit items 402 407 401 406 403 408 404 406 RefPart No Fluid Regulator Accessory Kit items 506 507 502 505 503Category Technical DataData Graco Information Graco Standard WarrantyToll Free