
|
| Electrical Tests |
Test Ground Strip Resistance |
|
|
See FIG. 22.. Using an ohmmeter, measure the resis- |
|
|
tance between the latch housing (206) and the ground | 209 | 214 |
lug (214). The ground strip is grounded through the cart |
back to the ground lug. Resistance must be less than 100 ohms. If greater than 100 ohms, replace the ground strip (240).
206
214
TI2165A
Fig. 22. Test Ground Strip Resistance
Test Cylinder Resistance
TI2164A
Fig. 23. Test Cylinder Resistance
See FIG. 23.. Remove the enclosure door. Using an ohmmeter, measure the resistance from the pump (209) to the ground lug (214). Resistance must be less than 100 ohms. If greater than 100 ohms, replace the grounding cylinder.
309293K | 33 |