Parts
Tubing and Wiring Chart
Use the diagrams on page 64 to find the connection points for the tubing and wiring listed below.
Code | Ref. | Length | Description |
No. | in. (mm) | ||
A1 | 248 | 20 (508) | 1/4 OD tube, regulator to pump |
A2 | 248 | 9 (229) | 1/4 OD tube, regulator (216) to mani- |
|
|
| fold |
B2 | 249 | 17 (432) | 5/32 OD tube, manifold air to door |
|
|
| interlock switch |
B3 | 249 | 20 (508) | 5/32 OD tube, valve tee to cylinder |
B4 | 249 | 5 (127) | 5/32 OD tube, regulator (216) to |
|
|
| gauge (2170 |
B5 | 249 | 22 (559) | 5/32 OD tube, valve tee to door inter- |
|
|
| lock switch |
C1 | 272 | 9 (229) | red 14 gauge wire from top of bleed |
|
|
| resistor to meter |
C2 | 251 | 8 (204) | green/yellow 14 gauge wire from |
|
|
| internal box ground lug to cylinder |
|
|
| cap |
C3 | 273 | 34 (864) | green/yellow 10 gauge wire from |
|
|
| external ground lug to cart |
C4 | 239 | n/a | green/yellow 25 ft ground wire with |
|
|
| clamp, from external ground lug to |
|
|
| true earth ground |
C5 | 243 | n/a | green/yellow 10 gauge wire from |
|
|
| external ground lug to ground probe |
C6 | 226 | n/a | red wire from bleed resistor to pump |
C7 | 272 | 16 (407) | red 14 gauge wire from pump to pail |
|
|
| cover with clamp |
C8 | 272 | 12 (305) | red 14 gauge wire from pump (209) |
|
|
| to ground on cylinder bracket |
C9 | 251 | n/a | green/yellow 10 gauge wire from |
|
|
| meter + to internal box ground lug |
E1 | 286 | 4 (102) | 3/8 OD tube, bulkhead to manifold |
309293K | 63 |