Graco Inc 244581, 309293K, 244582 important safety instructions Test Power Supply Resistance

Page 31

Electrical Tests

Test Power Supply Resistance

1.Prepare the gun for service as instructed on page 41.

2.Remove the power supply (18), page 46.

3.Remove the turbine alternator (19) from the power supply, page 47.

4.Measure resistance from the power supply's ground strips (EE) to the spring (18b). See FIG. 18..

5.The resistance should be 95-105 megohms. If out- side this range, replace the power supply. If in range, proceed to the next test.

6.Be sure the spring (18b) is in place before reinstall- ing the power supply.

18b

EE

ti1599a

Fig. 18. Test Power Supply Resistance

309293K

31

Image 31
Contents Instructions/Parts List Table of Contents Gun Model Description List of ModelsFM Approved EN 50059 CompliantElectric Shock Hazard SymbolsToxic Fluid Hazard Fire and Explosion HazardPressurized Equipment Hazard Equipment Misuse HazardHow the Electrostatic Air Spray Gun Works IntroductionSpraying Waterborne Fluids Electrostatically Gun Overview Gun OverviewSystem Requirements Install the System InstallationFire, Explosion, and Electric Shock Hazard Typical Installation PRO Xs Waterborne System Key Connect the Waterborne Fluid Hose Ventilate the Spray BoothConnect the Air Line Ground the CabinetUnshielded Hose Shielded HoseUnshielded fluid connection Waterborne Hose Dimensions At Graco WB100 EnclosureAgitator Kit Agitator KitFluid Regulator Kit Fluid Regulator KitFluid Nozzles Select a Fluid Nozzle and Air CapAir Caps Grounding Check Gun Grounding Check Electrical GroundingRelief Procedure on Operating ChecklistOperation Turn off the main air supply valve B Fill the Fluid Supply Adjust the Spray PatternFire and Explosion Hazard Fully open the fluid adjustment valve Air Hose Length Air Regulator Setting Ft m Psi MPa, bar Air Regulator SettingsWhen you finish spraying, perform the Shutdown procedure on Low Voltage Adjustment Low Voltage Adjustment Smart Guns OnlyShutdown Flush the Spray Gun MaintenanceDo not immerse the gun in fluid Daily Care and CleaningMaintenance Equipment Needed Clean the Air Cap and Fluid NozzleProcedure Grease Door Latch ThreadsTest Gun Resistance Electrical TestsTest Power Supply Resistance Test Power Supply ResistanceElectrode Test Electrode ResistanceTest Cylinder Resistance Test Ground Strip ResistanceWaterborne Fluid Hose TroubleshootingVoltage Loss Troubleshooting Spray GunTests Visual CheckTroubleshooting Spray Pattern Troubleshooting Gun Operation Troubleshooting Lowing the Fluid Voltage Discharge Grounding Procedure Electrical TroubleshootingSee Test Gun Resistance on 18 and Test Gun Resistance See Check Electrical Grounding onRepair Prepare the Gun for ServiceAir Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Packing Rod RepairBarrel Removal Barrel InstallationPower Supply Power Supply Removal and ReplacementTurbine Alternator Removal and Replacement Fan Air Adjustment Valve Fan Air Adjustment Valve RepairAir Valve Repair Fluid Adjustment Valve RepairES ON/OFF Valve Repair Atomizing Air Restrictor Valve Removal and ReplacementParts Ref. No Alternator 19a 19b Description Qty Hook 51 Ref 19a TI1487A Ti1601a Description Qty SWITCH, ES HI/LO TI2138a Plate DescriptionQty Code Length Description In. mm Tubing and Wiring ChartDetail of Door Interlock Switch Tubing and Wiring DiagramsDetail of Control Box Air Line Accessories AccessoriesFluid Line Accessories Miscellaneous Accessories Gun Accessories402 407 401 406 403 408 404 406 Ref Part No Agitator Accessory Kit items506 507 502 505 503 Part No Fluid Regulator Accessory Kit itemsCategory Technical DataData Graco Information Graco Standard WarrantyToll Free