Graco Inc 309293K, 244582, 244581 Turn off the main air supply valve B

Page 20

Operation

Fluid Voltage Discharge and

Pressure Relief Procedure

Grounding Procedure

 

WARNING

Electric Shock Hazard

The fluid supply is charged with high volt- age until the voltage is discharged. Contact

with the charged components of the isola- tion system or spray gun electrode will

cause an electric shock. To avoid an electric shock, follow the Fluid Voltage Discharge and Grounding Procedure:

whenever you are instructed to discharge the voltage

before cleaning, flushing, or servicing the system equipment

before approaching the front of the gun

or before opening the safety enclosure for the isolated fluid supply.

1.Turn the ES ON/OFF valve OFF and wait 30 sec- onds.

I ES O

ti1273a

2.Remove the door T-handle locking screw. This will shut off the air to the gun and trigger the grounding cylinder to discharge any remaining electrical charge.

3.Use the grounding rod to touch the pump and sup- ply pail. If you see any arcs, see Electrical Trouble- shooting on page 39.

WARNING

Pressurized Equipment Hazard

The system pressure must be manually

relieved to prevent the system from starting or spraying accidentally. To reduce the risk of an injury from electric shock, accidental spray from

the gun, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

are instructed to relieve the pressure

stop spraying

check or service any of the system equipment

or install or clean the fluid nozzle.

1.Turn the ES ON/OFF valve OFF.

I ES O

ti1273a

2.Follow the Fluid Voltage Discharge and Ground- ing Procedure at left.

3.Turn off the main air supply valve (B).

ti1289a

4.Trigger the gun into a grounded metal waste con- tainer to relieve the air and fluid pressure.

ti1276a

5.Relieve fluid pressure in the fluid supply unit as instructed in your fluid supply unit manual.

20

309293K

Image 20
Contents Instructions/Parts List Table of Contents List of Models FM ApprovedEN 50059 Compliant Gun Model DescriptionSymbols Electric Shock HazardFire and Explosion Hazard Toxic Fluid HazardEquipment Misuse Hazard Pressurized Equipment HazardSpraying Waterborne Fluids Electrostatically IntroductionHow the Electrostatic Air Spray Gun Works Gun Overview Gun OverviewFire, Explosion, and Electric Shock Hazard InstallationSystem Requirements Install the System Typical Installation PRO Xs Waterborne System Key Ventilate the Spray Booth Connect the Air LineGround the Cabinet Connect the Waterborne Fluid HoseShielded Hose Unshielded HoseWaterborne Hose Dimensions At Graco WB100 Enclosure Unshielded fluid connectionAgitator Kit Agitator KitFluid Regulator Kit Fluid Regulator KitAir Caps Select a Fluid Nozzle and Air CapFluid Nozzles Grounding Check Electrical Grounding Check Gun GroundingOperation Operating ChecklistRelief Procedure on Turn off the main air supply valve B Fire and Explosion Hazard Adjust the Spray PatternFill the Fluid Supply Fully open the fluid adjustment valve Air Regulator Settings Air Hose Length Air Regulator Setting Ft m Psi MPa, barWhen you finish spraying, perform the Shutdown procedure on Shutdown Low Voltage Adjustment Smart Guns OnlyLow Voltage Adjustment Maintenance Flush the Spray GunDaily Care and Cleaning Do not immerse the gun in fluidMaintenance Clean the Air Cap and Fluid Nozzle ProcedureGrease Door Latch Threads Equipment NeededElectrical Tests Test Gun ResistanceTest Power Supply Resistance Test Power Supply ResistanceTest Electrode Resistance ElectrodeTest Ground Strip Resistance Test Cylinder ResistanceTroubleshooting Voltage Loss TroubleshootingSpray Gun Waterborne Fluid HoseVisual Check TestsTroubleshooting Spray Pattern Troubleshooting Gun Operation Troubleshooting See Test Gun Resistance on Electrical TroubleshootingLowing the Fluid Voltage Discharge Grounding Procedure See Check Electrical Grounding on 18 and Test Gun ResistancePrepare the Gun for Service RepairAir Cap/Nozzle Replacement Electrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Repair Packing RodBarrel Installation Barrel RemovalPower Supply Removal and Replacement Power SupplyTurbine Alternator Removal and Replacement Fan Air Adjustment Valve Repair Fan Air Adjustment ValveFluid Adjustment Valve Repair Air Valve RepairAtomizing Air Restrictor Valve Removal and Replacement ES ON/OFF Valve RepairParts Ref. No Alternator 19a 19b Description Qty Hook 51 Ref 19a TI1487A Ti1601a Description Qty SWITCH, ES HI/LO TI2138a Plate DescriptionQty Tubing and Wiring Chart Code Length Description In. mmDetail of Control Box Tubing and Wiring DiagramsDetail of Door Interlock Switch Fluid Line Accessories AccessoriesAir Line Accessories Gun Accessories Miscellaneous AccessoriesPart No Agitator Accessory Kit items 402 407 401 406 403 408 404 406 RefPart No Fluid Regulator Accessory Kit items 506 507 502 505 503Data Technical DataCategory Toll Free Graco Standard WarrantyGraco Information