Dell E09J, E10J owner manual About the SCv2000/SCv2020 Storage System

Page 13

Item

Control/Feature

Icon

Description

 

 

 

 

3

MGMT port

10 Mbps, 100 Mbps, or 1 Gbps Ethernet port used for storage

 

 

 

system management and access to the BMC

 

 

 

NOTE: To use the MGMT port as an iSCSI port for

 

 

 

replication to another Storage Center, a Flex Port license

 

 

 

and replication license are required. To use the MGMT port

 

 

 

as a front-end connection to host servers, a Flex Port

 

 

 

license is required.

4

REPL port

10 Mbps, 100 Mbps, or 1 Gbps Ethernet/iSCSI port used for

 

 

 

replication to another Storage Center

 

 

 

NOTE: To use the RELP port as a front-end connection to

 

 

 

host servers, a Flex Port license is required.

5

SAS activity indicators

• Off: Port is off

 

 

 

• Steady green: Port is on, but without activity

 

 

 

• Blinking green: Port is on and there is activity

6

Storage controller

 

On: Storage controller completed POST

 

module status

 

 

7Recessed power off button

8Storage controller module fault

Powers down the storage controller if held for more than five seconds

Off: No faults

Steady amber: Firmware has detected an error

Blinking amber:Storage controller is performing POST

9Recessed reset button

10Identification LED

11USB port

12Diagnostic LEDs (8)

13Serial port (3.5 mm mini jack)

14Four or two iSCSI ports with two LEDs per port

15Mini-SAS port B

16Mini-SAS port A

Reboots the storage controller forcing it to restart at the POST process

• Off: Identification disabled

Blinking blue (for 15 sec.): Identification is enabled

Blinking blue (continuously): Storage controller shut down to the Advanced Configuration and Power Interface (ACPI) S5 state

Not for customer use on SCv2000/SCv2020 Storage Systems.

• Green LEDs 0–3: Low byte hex POST code

• Green LEDs 4–7: High byte hex POST code

Not for customer use.

• Off: No power

Steady Amber: Link

Blinking Green: Activity

Back-end expansion port B

Back-end expansion port A

About the SCv2000/SCv2020 Storage System

13

Image 13
Contents Dell Storage Center Page Contents SCv2000/SCv2020 Technical Specifications Troubleshooting SCv2000/SCv2020 ComponentsAudience Contacting Dell Revision HistoryRelated Publications Dell Enterprise Manager Administrator’s Guide SCv2000/SCv2020 Storage System Hardware SCv2000/SCv2020 Monitoring and DiagnosticsSCv2000 Front Panel View SCv2000/SCv2020 Back Panel View SCv2000/SCv2020 Back-Panel Features and Indicators SCv2000/SCv2020 Storage Controller Features and Indicators About the SCv2000/SCv2020 Storage System About the SCv2000/SCv2020 Storage System About the SCv2000/SCv2020 Storage System SCv2000/SCv2020 Storage Controller with SAS Front-End Ports SCv2000/SCv2020 Drives SCv2000/SCv2020 Drive IndicatorsAbout the SCv2000/SCv2020 Storage System Installation Safety Precautions Safety PrecautionsElectrostatic Discharge Precautions Electrical Safety PrecautionsGeneral Safety Precautions Sending Diagnostic Data Using Dell SupportAssist Pre-Replacement ProceduresShutting Down a Storage Controller Shutting Down the Storage SystemIdentifying the Failed Power Supply Replacing Power Supply/Cooling Fan ModulesReplacing the Front Bezel Page Identifying the Failed Cooling Fan Rear View of the Enclosure Showing the Failed Cooling Fan Replacing a Power Supply/Cooling Fan ModuleRemoving a Power Supply/Cooling Fan Module SCv2000/SCv2020 Storage System Drive Numbering Replacing Hard DrivesIdentifying the Failed Hard Drive Front View of the Enclosure Showing the Failed Hard Drive Replacing a Hard Drive Replacing a Hard DriveInstall Hard Drives in Storage System Replacing a Storage Controller Replacing the Storage Controller BatteryIdentify the Failed Storage Controller Replace a Single Storage Controller Replacing a Storage Controller Replace Both Storage Controllers in Succession Replacing a Storage Controller Replace Both Storage Controllers Simultaneously Replacing Rack RailsStart up the Storage System Post-Replacement ProceduresTroubleshooting Hard Drives Troubleshooting Power Supply/Cooling Fan ModulesTroubleshooting Storage Controllers Technical Specifications SCv2000/SCv2020 Technical SpecificationsSCv2000/SCv2020 Technical Specifications Hour SCv2000/SCv2020 Technical Specifications