SCv2000/SCv2020 Storage Controller with SAS Front-End Ports
Features and indictors on a storage controller with SAS
Figure 7. SCv2000/SCv2020 Storage Controller with Four 12 Gb SAS Front-End Ports
Item | Control/Feature | Icon Description |
|
|
|
1 | Battery status indicator | • Blinking green (on 0.5 sec. / off 1.5 sec.): Battery heartbeat |
•Fast blinking green (on 0.5 sec. / off 0.5 sec.): Battery is charging
•Steady green: Battery is ready
2 | Battery fault indicator | • Off: No faults |
•Blinking amber: Correctable fault detected
•Steady amber: Uncorrectable fault detected; replace battery
3 | MGMT port | — | 10 Mbps, 100 Mbps, or 1 Gbps Ethernet port used for storage |
|
|
| system management and access to the BMC |
|
|
| NOTE: To use the MGMT port as an iSCSI port for |
|
|
| replication to another Storage Center, a Flex Port license |
|
|
| and replication license are required. To use the MGMT port |
|
|
| as a |
|
|
| license is required. |
4 | REPL port | — | 10 Mbps, 100 Mbps, or 1 Gbps Ethernet/iSCSI port used for |
|
|
| replication to another Storage Center |
|
|
| NOTE: To use the RELP port as a |
|
|
| host servers, a Flex Port license is required. |
5 | SAS activity indicators | — | • Off: Port is off |
|
|
| • Steady green: Port is on, but without activity |
|
|
| • Blinking green: Port is on and there is activity |
6 | Storage controller |
| On: Storage controller completed POST |
| module status |
|
|
7Recessed power off button
8Storage controller module fault
Powers down the storage controller if held for more than five seconds
•Off: No faults
•Steady amber: Firmware has detected an error
•Blinking amber:Storage controller is performing POST
14 | About the SCv2000/SCv2020 Storage System |