3.Expand the failed storage system entry.

4.In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed power supply.

Figure 10. Hardware Alert Identifying the Enclosure with the Failed Power Supply

5.In the Hardware tab navigation pane, expand the enclosure identified in the previous step and select Power Supplies. The status of each power supply is displayed in the Power Supplies tab.

6.Select the failed power supply. The location of the failed power supply is displayed in the Power Supply View tab.

Figure 11. Rear View of the Enclosure Showing the Failed Power Supply

Replacing SCv2000/SCv2020 Components

21

Image 21
Contents Dell Storage Center Page Contents SCv2000/SCv2020 Technical Specifications Troubleshooting SCv2000/SCv2020 ComponentsRevision History Audience Contacting DellRelated Publications Dell Enterprise Manager Administrator’s Guide SCv2000/SCv2020 Storage System Hardware SCv2000/SCv2020 Monitoring and DiagnosticsSCv2000 Front Panel View SCv2000/SCv2020 Back Panel View SCv2000/SCv2020 Back-Panel Features and IndicatorsSCv2000/SCv2020 Storage Controller Features and Indicators About the SCv2000/SCv2020 Storage System About the SCv2000/SCv2020 Storage System About the SCv2000/SCv2020 Storage System SCv2000/SCv2020 Storage Controller with SAS Front-End Ports SCv2000/SCv2020 Drives SCv2000/SCv2020 Drive IndicatorsAbout the SCv2000/SCv2020 Storage System Installation Safety Precautions Safety PrecautionsElectrical Safety Precautions Electrostatic Discharge PrecautionsGeneral Safety Precautions Sending Diagnostic Data Using Dell SupportAssist Pre-Replacement ProceduresShutting Down a Storage Controller Shutting Down the Storage SystemReplacing Power Supply/Cooling Fan Modules Identifying the Failed Power SupplyReplacing the Front Bezel Page Identifying the Failed Cooling Fan Rear View of the Enclosure Showing the Failed Cooling Fan Replacing a Power Supply/Cooling Fan ModuleRemoving a Power Supply/Cooling Fan Module Replacing Hard Drives SCv2000/SCv2020 Storage System Drive NumberingIdentifying the Failed Hard Drive Front View of the Enclosure Showing the Failed Hard Drive Replacing a Hard Drive Replacing a Hard DriveInstall Hard Drives in Storage System Replacing a Storage Controller Replacing the Storage Controller BatteryIdentify the Failed Storage Controller Replace a Single Storage Controller Replacing a Storage Controller Replace Both Storage Controllers in Succession Replacing a Storage Controller Replace Both Storage Controllers Simultaneously Replacing Rack RailsStart up the Storage System Post-Replacement ProceduresTroubleshooting Hard Drives Troubleshooting Power Supply/Cooling Fan ModulesTroubleshooting Storage Controllers Technical Specifications SCv2000/SCv2020 Technical SpecificationsSCv2000/SCv2020 Technical Specifications Hour SCv2000/SCv2020 Technical Specifications