Dell E10J, E09J owner manual Removing a Power Supply/Cooling Fan Module

Page 24

Figure 14. Removing a Power Supply/Cooling Fan Module

1. Power supply/cooling fan module

2. Storage system chassis

4.Slide the replacement power supply/cooling fan module into the chassis until it is fully seated and the release tab clicks into place.

5.Connect the power cable to the power supply/cooling fan module and make sure that the cable is plugged into a power outlet.

6.Secure the power cable using the hook-and-loop strap.

Figure 15. Securing the Power Cable

7.Press the power switch on the power supply/cooling fan module to turn it on.

NOTE: Allow several seconds for the storage system to recognize the power supply/cooling fan module and determine its status. When the power supply/cooling fan module is functioning properly, the AC power status indicator turns green and the three fault indicators are off.

8.In the Dell Storage Client, make sure that the replacement power supply/cooling fan module is recognized and shown as up and running.

Next steps

1.Use SupportAssist to send diagnostic data to Dell Technical Support Services.

24

Replacing SCv2000/SCv2020 Components

Image 24
Contents Dell Storage Center Page Contents Troubleshooting SCv2000/SCv2020 Components SCv2000/SCv2020 Technical SpecificationsRevision History Audience Contacting DellRelated Publications Dell Enterprise Manager Administrator’s Guide SCv2000/SCv2020 Monitoring and Diagnostics SCv2000/SCv2020 Storage System HardwareSCv2000 Front Panel View SCv2000/SCv2020 Back-Panel Features and Indicators SCv2000/SCv2020 Back Panel ViewSCv2000/SCv2020 Storage Controller Features and Indicators About the SCv2000/SCv2020 Storage System About the SCv2000/SCv2020 Storage System About the SCv2000/SCv2020 Storage System SCv2000/SCv2020 Storage Controller with SAS Front-End Ports SCv2000/SCv2020 Drive Indicators SCv2000/SCv2020 DrivesAbout the SCv2000/SCv2020 Storage System Safety Precautions Installation Safety PrecautionsElectrical Safety Precautions Electrostatic Discharge PrecautionsGeneral Safety Precautions Pre-Replacement Procedures Sending Diagnostic Data Using Dell SupportAssistShutting Down a Storage Controller Shutting Down the Storage SystemReplacing Power Supply/Cooling Fan Modules Identifying the Failed Power SupplyReplacing the Front Bezel Page Identifying the Failed Cooling Fan Replacing a Power Supply/Cooling Fan Module Rear View of the Enclosure Showing the Failed Cooling FanRemoving a Power Supply/Cooling Fan Module Replacing Hard Drives SCv2000/SCv2020 Storage System Drive NumberingIdentifying the Failed Hard Drive Front View of the Enclosure Showing the Failed Hard Drive Replacing a Hard Drive Replacing a Hard DriveInstall Hard Drives in Storage System Replacing the Storage Controller Battery Replacing a Storage ControllerIdentify the Failed Storage Controller Replace a Single Storage Controller Replacing a Storage Controller Replace Both Storage Controllers in Succession Replacing a Storage Controller Replacing Rack Rails Replace Both Storage Controllers SimultaneouslyPost-Replacement Procedures Start up the Storage SystemTroubleshooting Power Supply/Cooling Fan Modules Troubleshooting Hard DrivesTroubleshooting Storage Controllers SCv2000/SCv2020 Technical Specifications Technical SpecificationsSCv2000/SCv2020 Technical Specifications Hour SCv2000/SCv2020 Technical Specifications