Dell E09J, E10J owner manual SCv2000/SCv2020 Technical Specifications

Page 39

4

SCv2000/SCv2020 Technical

Specifications

This section contains technical specifications of the SCv2000/SCv2020 storage system.

Technical Specifications

The technical specifications of the SCv2000/SCv2020 storage systems are displayed in the following tables.

Drives

SAS hard drives

SCv2000: Up to 12 3.5-inch SAS hot-swappable hard drives (6.0 Gbps)

 

SCv2020: Up to 24 2.5-inch SAS hot-swappable hard drives (6.0 Gbps)

 

 

Storage Controllers

 

 

 

Storage controllers

Up to two hot-swappable storage controllers with the following IO options:

 

• Two 16 Gbps Fibre Channel ports

 

• Four 8 Gbps Fibre Channel ports

 

• Two 10 Gbps iSCSI ports

 

• Four 1 Gbps iSCSI ports

 

• Four 12 Gbps SAS ports

 

 

Storage Connectivity

 

 

 

Configurations

Storage Center supports up to 168 drives in one redundant-path SAS chain

 

• An SCv2000 supports up to 13 SC100 expansion enclosures or 6 SC120

 

expansion enclosures

 

• An SCv2020 supports up to 12 SC100 expansion enclosures or 6 SC120

 

expansion enclosures

Redundant Array of Independent Disks (RAID)

Controller

Two hot-swappable storage controllers

Management

RAID management using Dell Storage Client 2015 R1

SCv2000/SCv2020 Technical Specifications

39

Image 39
Contents Dell Storage Center Page Contents SCv2000/SCv2020 Technical Specifications Troubleshooting SCv2000/SCv2020 ComponentsRevision History Audience Contacting DellRelated Publications Dell Enterprise Manager Administrator’s Guide SCv2000/SCv2020 Storage System Hardware SCv2000/SCv2020 Monitoring and DiagnosticsSCv2000 Front Panel View SCv2000/SCv2020 Back Panel View SCv2000/SCv2020 Back-Panel Features and IndicatorsSCv2000/SCv2020 Storage Controller Features and Indicators About the SCv2000/SCv2020 Storage System About the SCv2000/SCv2020 Storage System About the SCv2000/SCv2020 Storage System SCv2000/SCv2020 Storage Controller with SAS Front-End Ports SCv2000/SCv2020 Drives SCv2000/SCv2020 Drive IndicatorsAbout the SCv2000/SCv2020 Storage System Installation Safety Precautions Safety PrecautionsElectrical Safety Precautions Electrostatic Discharge PrecautionsGeneral Safety Precautions Shutting Down the Storage System Pre-Replacement ProceduresSending Diagnostic Data Using Dell SupportAssist Shutting Down a Storage ControllerReplacing Power Supply/Cooling Fan Modules Identifying the Failed Power SupplyReplacing the Front Bezel Page Identifying the Failed Cooling Fan Rear View of the Enclosure Showing the Failed Cooling Fan Replacing a Power Supply/Cooling Fan ModuleRemoving a Power Supply/Cooling Fan Module Replacing Hard Drives SCv2000/SCv2020 Storage System Drive NumberingIdentifying the Failed Hard Drive Front View of the Enclosure Showing the Failed Hard Drive Replacing a Hard Drive Replacing a Hard DriveInstall Hard Drives in Storage System Replacing a Storage Controller Replacing the Storage Controller BatteryIdentify the Failed Storage Controller Replace a Single Storage Controller Replacing a Storage Controller Replace Both Storage Controllers in Succession Replacing a Storage Controller Replace Both Storage Controllers Simultaneously Replacing Rack RailsStart up the Storage System Post-Replacement ProceduresTroubleshooting Hard Drives Troubleshooting Power Supply/Cooling Fan ModulesTroubleshooting Storage Controllers Technical Specifications SCv2000/SCv2020 Technical SpecificationsSCv2000/SCv2020 Technical Specifications Hour SCv2000/SCv2020 Technical Specifications