Carrier 19XRV specifications A19-1848, Frame 6 Parts

Page 27

a19-1848

NOTE: When replacing the Main Control Board (Item No. 1) the jumper marked “J1 ENABLE” must be removed and the jumper marked “J1 SAFETY” must be left in place.

LEGEND

1PF750 Series, Precharge Kit

2PF750 Series, Gate Interface

3PF750 Series, Power Interface

4PowerFlex 750 Series, Flange Gasket

5PF755 Main Control Board

6PF750 Series, Backplane Interface

7PF750 Series, Type 4X/12 Chill Plate (Heatsink) Fan Kit

8Chill Plate Fan

Fig. 27 — Frame 6 Parts

 

LEGEND

 

1

Slot for Gateway (Gateway Not Shown)

 

2

PF750 Series, Backplane Interface

 

3

PF750 Series, Type 4X/12 Heatsink Fan Kit

 

4

PF750 Series, Power Interface

 

5

PF750 Series, Bus Cap Assembly

 

6

PF750 Series, Power Interface Cable

 

7

PF750 Series, Current Transducer Kit

 

8

PF750 Series, Precharge Kit

 

9

Slot for 24V I/O Module (24V I/O Module Not Shown)

 

10

PF755 Main Control Board

 

NOTE: When replacing the Main Control Board (Item No. 1) the jumper marked “J1 ENABLE” must be

a19-1849

removed and the jumper marked “J1 SAFETY” must be left in place.

Fig. 28 — Frame 7 Parts

27

Image 27
Contents Start-Up and Service Instructions Contents A19-1831 A19-1842A19-1814 A19 1832A19-1833 A19-1834 Wire LugsVFD Configurations Parameter Default ValueA19 1846 TB1 I/O Terminal Designations A19-1921A19-1835 A19-18361815 Link Drive Status Indicator DescriptionsName Color State Description EnetA19-1925 A19-1844Alert Icvc Alert CodesMessage PrestartLimited RUN CapacityLOW OIL FaultPrimary Secondary Primary Cause Additional CAUSE/REMEDY Sensor AlertSystem Alert LossCommunication VFD Speed AlertFailure to Stop Icvc Alarm CodesProtective Limit 236 233234 235Unused State UnusedVFD Gateway Sensor FaultHist Screen None Fault Type Description Corrective Action On VFDVFD Code124 Hist ScreenNone 113Meter Lead Meter Reading Diode ChecksA19-1816Fig Removing Enclosure A19-1831Fig Open Access DoorFrames 6 and 7 Power Terminal Block A19-1814Fig Check DC Bus TerminalsA19-1837 A19-1838A19-1817A19-1818 A19-1819 Comm CardTB4 Dist Side A19-1847CR1 EA1 Line CR6 CB1 TB4 CB2 FU1-FU3 PT1 Secondary Side Toward DoorFrame 6 Parts A19-1848A19-1946 Appendix a Wiring Schematics Chiller Control SchematicUPC A19-1947Hgbp RHSA19-1966 Shld A19-1967A48-8579 A48-8578A48 8580 Appendix B Optional Bacnet Communications WiringTable a SW3 Protocol Switch Settings For MS/TP Table B Baud Selection TableA48-8582 Table C MS/TP Wiring RecommendationsWiring Specifications Recommended Vendors and Part Numbers RmcorpCMP Run Table E LED Status IndicatorsRUN LED Error LED Status LED StatusObject ID Object Name CHW Page Copyright 2011 Carrier Corporation

19XRV specifications

The Carrier 19XRV is a cutting-edge rooftop chiller designed to provide reliable and efficient cooling solutions for a wide range of applications, including commercial buildings and industrial facilities. This advanced system integrates the latest technologies and innovative features to ensure optimal performance, energy efficiency, and ease of use.

One of the most prominent features of the 19XRV is its advanced inverter-driven compressor technology. This allows the chiller to adjust its capacity seamlessly based on the building's cooling demand. By varying the speed of the compressor, the 19XRV maximizes energy efficiency and minimizes operational costs, especially during partial load conditions. This capability not only enhances comfort but also contributes to reduced energy consumption, making it a sustainable choice for environmentally conscious users.

In addition to the inverter technology, the 19XRV incorporates a microchannel coil design. This design optimizes heat exchange efficiency and reduces the refrigerant charge, which is an essential factor in lowering greenhouse gas emissions. The microchannel coils also allow for more compact dimensions, making installation easier and maximizing rooftop space usage.

Another significant aspect of the Carrier 19XRV is its robust controls system. Equipped with Carrier’s advanced ComfortLink™ controls, this chiller offers precise monitoring and control over its operation. Users can easily integrate the chiller into building management systems for real-time data access and efficiency analytics. This connectivity ensures that operators can make informed decisions to optimize performance continuously.

The 19XRV also includes features aimed at enhancing reliability and durability. Its structural design incorporates corrosion-resistant materials, allowing the unit to withstand harsh environmental conditions. This reliability translates to lower maintenance requirements and extended equipment lifespan, providing excellent value over time.

Moreover, the chiller is designed for quiet operation, making it suitable for applications where low noise levels are essential. Sound-dampening measures ensure that the 19XRV can be utilized in urban environments or near sensitive areas without causing disturbances.

In conclusion, the Carrier 19XRV is a state-of-the-art rooftop chiller that combines efficiency, technology, and durability. Its inverter-driven compressor, microchannel coil design, advanced controls, and robust construction make it an ideal choice for those looking to maintain comfort while minimizing energy usage and environmental impact. Whether for commercial or industrial applications, the 19XRV stands out as a reliable and innovative cooling solution for the modern age.