IDEAL INDUSTRIES 61-340 Specifications, General specifications Characteristics Description

Page 5

Page 3

SPECIFICATIONS

All specifications are warranted unless noted typical and apply to the 61-340 & 61-342

Stated accuracies are at 23°C±5°C at less than 75% relative humidity and without the battery indicator displayed.

General specifications

Characteristics

Description

 

 

 

Display count

3 3/4 digit liquid crystal display, max count 4000

 

 

 

Numeric update rate

2.5 times / sec

 

 

 

 

Polarity display

Automatic

 

 

 

 

Over range display

“OL” is displayed

 

 

 

 

Low battery indicator

is indicated

 

 

 

Automatic power-off time

Automatic power off ≈ 10minutes

 

 

Power source

9.0V battery: types- NEDA 1604, JIS006P, IEC6F22

for both 61-340 and

61-342

 

 

 

*Maximum input voltage

1000Vrms CAT III between V and COM

 

 

*Maximum floating voltage

1000Vrms CAT III between any terminal and earth ground

 

 

Maximum input current

400mA between µA /mA and COM

 

 

Overload protection mA connector

500mA (250V) fast blow fuse.

 

 

Overload protection 10A connector

10A (250V) fast blow fuse.

 

 

 

V connector

V , V , , ,

, , Hz

 

 

 

µA /mA connector

µA, mA, Temp

 

 

 

Temperature Coefficient

0.1×(Spec. Accuracy) per °C, <18°C or >28°C

 

 

Battery Life

Alkaline 9V, ≈ 200 hours for 61-340

Alkaline 9V, ≈ 150 hours for 61-342

 

 

 

 

Form Number TM61340-2

Rev 2 November 2007

Image 5
Contents Ideal INDUSTRIES, INC. Technical Manual Table of Contents Introduction Table A. The SymbolsSafety General specifications Characteristics Description SpecificationsRange Resolution Accuracy Input Protection Range Resolution Accuracy Over voltage ProtectionInput Impedance 10MΩ Frequency response 40~400HzRange Resolution Accuracy Range Resolution Accuracy Max. Test Max. Open Current Range Range Resolution Sensitivity AccuracyOverload Protection 16 MAX/MIN 8 14 REL15 Hz/DUTY Certifications and compliances Physical and Environmental Characteristics DescriptionEnvironmental characteristics Description AC Voltage Range 0 ~ 750V AC Required EquipmentFrequency Range 40 ~ 1KHz Accuracy ±2% DC Voltage Range 0 ~ 1000V DCOpening the Meter Case Replacing the BatteryReplacing Fuses Fuse ReplacementLCD Graphics 61-340 Testing the DisplayStep Range Input Reading Testing the Voltage Function for 61-340Testing the DC milli amperes Function for 61-340 Testing the DC microamperes Function for 61-340Step Range Input Frequency Reading Step Range SourceStep Range Source Frequency Reading Testing the DC ampere Function for 61-340Testing the AC microampere Function for 61-340 Step Source Frequency Reading Testing the AC milliampere function for 61-340andTesting the AC a function for 61-340 Step Range Source Reading Testing the Resistance Function for 61-340Testing the Capacitance Function for 61-340 Checking the Continuity Function for 61-340 Checking the Diode Test Function for 61-340Testing the Duty Cycle Function for 61-340 Testing the Frequency Function for 61-340Testing the Temperature Function for 61-340 AC V Calibration Adjust VR2 Model DC V Calibration Adjust VR1Temp Calibration Adjust VR3