Carrier 50PEC09-18 specifications 50PEC18 Chassis Dimensions Front Return

Page 16

 

 

46.98

 

 

(1193)

20.50

 

Blower Deck

 

 

(521)

 

 

 

 

Filter

 

0.75

Blower Screen

 

(19)

 

 

 

 

36.00

 

 

(914)

Control Box

Compressor

Access

Panel

7.38

(187)

4.46

(113)

0.75 (19)

Hard Wire

Power Supply

5.36

 

(187)

 

 

3.01

 

 

(76)

 

30˚

 

Optional

 

0.87

 

Autoflow

 

(22)

 

 

Valve

16.66

 

 

(423)

 

Optional

 

 

 

 

Motorized

 

7.5

Water Valve

 

(191)

 

 

3.56

 

 

(90)

 

 

3.43

 

 

(87)

 

11.54

 

 

(293)

 

 

Optional Fused Disconnect Box (mounted to cabinet not chassis)

Power supply enters

Bottom of Box

Optional Disconnect

Only Box (All Configurations)

Power supply enters

Bottom of Box

 

 

 

 

4.56

 

 

 

 

 

(116)

 

 

 

Right Hand Configuration

4.46

 

 

 

 

 

(113)

 

16

5.36

Hard Wire

Optional

 

 

(136)

Power Supply

Autoflow

46.98

 

 

 

 

3.01

 

Valve

(1193)

 

 

 

Optional

 

 

(76)

 

 

 

 

0.87

 

Motorized

 

 

 

(22)

30˚

Water Valve

 

 

Optional

 

 

 

 

 

 

 

 

Autoflow

 

 

 

 

Control Box

Valve

 

 

 

 

 

 

 

 

 

 

3.42

 

 

 

 

Optional

(87)

16.66

 

Blower Deck

 

Motorized

 

(423)

 

 

 

 

 

 

Water Valve

 

 

 

 

 

 

7.50

 

 

 

 

 

(191)

 

 

 

Compressor

 

 

 

 

 

 

 

 

 

 

Access

 

3.56

 

 

 

Panel

 

 

 

Filter

7.38

 

(90)

 

 

(187)

 

 

 

4.49

 

 

 

 

 

(114)

 

 

Optional

 

 

0.75

 

0.75

11.54

 

(19)

Blower Screen

Disconnect Box

 

(19)

(293)

 

 

36.00

 

(mounted to cabinet

 

 

 

 

 

 

(914)

 

not chassis)

 

 

 

 

 

 

 

 

 

Power supply enters

 

Left Hand Configuration

 

 

Bottom of Box

 

 

 

 

 

20.50

(521)

NOTES:

1.Dimensions shown are in inches. Dimensions in parentheses are in millimeters.

2.Optional autoflow valve, motorized water valve and disconnect box are shown.

3.Chassis can mount directly on floor.

Fig. 14 — 50PEC18 Chassis Dimensions — Front Return

Image 16
Contents Contents Safety ConsiderationsGeneral Installation50PEC Physical Data OUT Water OUTCondensate A50-8335Water 22.2 ODA50-8337 A50-8338A50-8339 Damper Opening50PEC18 Bottom Return Cabinet Dimensions Right Hand Piping 50PEC09-15 Bottom Return Cabinet Dimensions Left Hand Piping 50PEC18 Bottom Return Cabinet Dimensions Left Hand Piping 50PEC09-15 Front Return Cabinet Dimensions Right Hand Piping 50PEC18 Front Return Cabinet Dimensions Right Hand Piping 50PEC09-15 Front Return Cabinet Dimensions Left Hand Piping A50-834550PEC18 Front Return Cabinet Dimensions Left Hand Piping A50-8347 50PEC09-15 Chassis Dimensions Front Return Optional Autoflow Valve MotorizedOptional Fused Optional Disconnect Box AutoflowOptional Motorized Water Valve Optional Autoflow50PEC18 Chassis Dimensions Front Return Wire Electrical Connections Mount UnitA50-8452 09-18A50-8327.eps A50-8328 Sensor, Water Coil Freeze ProtectionA50-8329 Night Low Limit SwitchReturn Air Sensor Blower Motor Wiring NLL PremierLink Controller Applications with Complete C Control A50-8355 A50 8354LWT 8353 A50-8380 Wshp Open ControlWire Low Voltage Connections Electrical Data 50PEC UnitsA50-7467tf A50-8441Field-Supplied Sensors for Wshp Open Controller Recommended Thermostat Wire SizesSPT Sensors Install Supply and Return Piping Rnet Wiring SpecificationsRnet Wiring A50-8443PRE-START-UP Temporary Connection for Flushing System PipingAir and Water Limits Min Ambient Air Rated Ambient Air Max Ambient AirMin Entering Air Rated Entering Air, dry bulb/wet bulb Max Entering Air, dry bulb/wet bulbWater Quality Guidelines Complete C Control Jumper Settings See , 18, Deluxe D Control Jumper Settings See , 20,DIP Switch Block S2 Accessory 1 Relay Options Field Selectable InputsDIP Switch Block S2 Accessory 2 Relay Options START-UPUnit Start-Up/Cooling Operating LimitsUnit Start-Up with Wshp Open Controls BACview6 Display InterfaceCoaxial Water Pressure Drop GPMApproximate Fluid Volume gal Per 100 ft of Pipe Antifreeze Percentages by VolumeOperation Units with Aquazone Complete C ControlUnits with Wshp Open Multiple Protocol Page Complete C and Deluxe D Board System Test Complete C Control LED Code and Fault Descriptions Aquazone Deluxe D Control LED IndicaService Gravity Flow Method Troubleshooting Refrigerant ChargingAir Coil Fan Motor Removal Replacing the Wshp Open Controller’s BatTroubleshooting Fault Heating Cooling Possible Cause SolutionUnit Does Not Operate Appendix a Wshp Open Screen Configuration Alarm StatusStatus SensorAppendix a Wshp Open Screen Configuration MaintenanceSystem Settings ConfigurationOptimal Start ScheduleService Appendix a Wshp Screen Open ConfigurationTest Configuration Service Point Name Password Editable Range Default LevelHigh Alarm Limit AlarmPage Page Copyright 2009 Carrier Corporation 50PEC Unit START-UP Checklist II. START-UPHeating Cycle Analysis Cooling Cycle AnalysisA50-8453 A50-8454