Carrier 50PEC09-18 specifications PremierLink Controller Applications with Complete C Control

Page 24

 

LEGEND

CR —

Control Relay

LWT —

Leaving Water Temperature Sensor

SAT —

Supply Air Temperature Sensor

SPT —

Space Temperature Sensor

NOTE: Reversing valve is on in Cooling mode.

PWR

J6J5

PREMIER

LINK

PWR

HS1/EXH/RVS

CR

CMP1

FAN

J1 J8

J4

COMPLETE

C

CONTROL

Y

W

CR

O

G

R

C

AL1

AL2

A

S

S

L

CMPSAFE

 

P

A

W

 

T

T

T

 

Fig. 23 — PremierLink™ Controller Applications with Complete C Control

PREMIER

LINK

PWR

 

 

HS2

 

 

HS1

 

LEGEND

CMP2

LWT — Leaving Water Temperature Sensor

 

SAT — Supply Air Temperature Sensor

 

SPT — Space Temperature Sensor

 

NOTE: Reversing valve is on in Cooling mode.

CMP1

 

 

FAN

 

 

J8

 

PWR

J1

J6

J5

J4

S

S

L

CMPSAFE

 

P

A

W

 

T

T

T

 

DELUXE

D

CONTROL

Y1

Y2

W1

O/W2

G

R

C

AL1

Fig. 24 — PremierLink Controller Applications with Deluxe D Control

24

Image 24
Contents Contents Safety ConsiderationsInstallation General50PEC Physical Data OUT Water OUTCondensate A50-8335Water 22.2 ODA50-8337 A50-8338A50-8339 Damper Opening50PEC18 Bottom Return Cabinet Dimensions Right Hand Piping 50PEC09-15 Bottom Return Cabinet Dimensions Left Hand Piping 50PEC18 Bottom Return Cabinet Dimensions Left Hand Piping 50PEC09-15 Front Return Cabinet Dimensions Right Hand Piping 50PEC18 Front Return Cabinet Dimensions Right Hand Piping 50PEC09-15 Front Return Cabinet Dimensions Left Hand Piping A50-834550PEC18 Front Return Cabinet Dimensions Left Hand Piping A50-8347 50PEC09-15 Chassis Dimensions Front Return Optional Autoflow Valve MotorizedOptional Fused Optional Disconnect Box AutoflowOptional Motorized Water Valve Optional Autoflow50PEC18 Chassis Dimensions Front Return Wire Electrical Connections Mount UnitA50-8452 09-18A50-8327.eps A50-8328 Sensor, Water Coil Freeze ProtectionNight Low Limit Switch A50-8329Return Air Sensor Blower Motor Wiring NLL PremierLink Controller Applications with Complete C Control A50-8355 A50 8354LWT 8353 A50-8380 Wshp Open ControlWire Low Voltage Connections Electrical Data 50PEC UnitsA50-7467tf A50-8441Recommended Thermostat Wire Sizes Field-Supplied Sensors for Wshp Open ControllerSPT Sensors Install Supply and Return Piping Rnet Wiring SpecificationsRnet Wiring A50-8443PRE-START-UP Temporary Connection for Flushing System PipingAir and Water Limits Min Ambient Air Rated Ambient Air Max Ambient AirMin Entering Air Rated Entering Air, dry bulb/wet bulb Max Entering Air, dry bulb/wet bulbWater Quality Guidelines Complete C Control Jumper Settings See , 18, Deluxe D Control Jumper Settings See , 20,DIP Switch Block S2 Accessory 1 Relay Options Field Selectable InputsDIP Switch Block S2 Accessory 2 Relay Options START-UPUnit Start-Up/Cooling Operating LimitsUnit Start-Up with Wshp Open Controls BACview6 Display InterfaceCoaxial Water Pressure Drop GPMApproximate Fluid Volume gal Per 100 ft of Pipe Antifreeze Percentages by VolumeOperation Units with Aquazone Complete C ControlUnits with Wshp Open Multiple Protocol Page Complete C and Deluxe D Board System Test Complete C Control LED Code and Fault Descriptions Aquazone Deluxe D Control LED IndicaService Gravity Flow Method Troubleshooting Refrigerant ChargingAir Coil Fan Motor Removal Replacing the Wshp Open Controller’s BatTroubleshooting Fault Heating Cooling Possible Cause SolutionUnit Does Not Operate Appendix a Wshp Open Screen Configuration Alarm StatusStatus SensorAppendix a Wshp Open Screen Configuration MaintenanceSystem Settings ConfigurationOptimal Start ScheduleAppendix a Wshp Screen Open Configuration ServiceTest Configuration Service Point Name Password Editable Range Default LevelHigh Alarm Limit AlarmPage Page Copyright 2009 Carrier Corporation 50PEC Unit START-UP Checklist II. START-UPHeating Cycle Analysis Cooling Cycle AnalysisA50-8453 A50-8454