Carrier 50PEC09-18 specifications 50PEC09-15 Front Return Cabinet Dimensions Right Hand Piping

Page 9

 

 

16.0

5.0

DISCHARGE

 

 

(406)

(127)

AIR

 

 

 

 

30˚

 

 

CONTROL ACCESS DOOR

 

 

21.0

 

FRONT VIEW

 

SIDE

 

 

 

VIEW

(533)

 

 

 

 

 

 

 

7.9

AIR

 

 

 

(201) INLET

 

 

43.7

 

12.0

 

 

(1110)

 

 

 

48.0

 

(305)

 

 

(1219)

 

 

 

 

Filter located behind return

 

 

 

 

air grille and requires removal of

 

 

 

 

cabinet front for access.

 

 

 

 

48.0

 

 

 

 

(1219)

 

.50 (13)

 

 

 

 

12.0

 

BOTTOM VIEW

11.50

 

(305)

 

 

 

 

(292)

R.H. PIPE AND

 

 

 

 

 

 

 

ELECTRIC AREA

 

 

 

.75 (19)

1.0 (25)

4.5

4.12

 

 

 

(114)

(105)

 

 

 

 

 

 

1.0 (25)

 

 

 

 

 

 

REAR VIEW

 

 

 

 

20.0

21.0

 

R.H.

 

(508)

(533)

 

 

 

 

REAR

 

 

 

 

ACCESS

 

 

 

 

(NOTE 2)

 

 

 

 

 

 

48.0

 

 

 

 

(1219)

 

 

NOTES:

1.Dimensions are shown in inches. Dimensions in parentheses are in millimeters.

2.Access is reduced if optional disconnect box is selected.

3.Optional autoflow valve, motorized water valve and disconnect box are shown.

Fig. 7 — 50PEC09-15 Front Return Cabinet Dimensions — Right Hand Piping

3.5 (89)

21.0 (533)

9

Image 9
Contents Safety Considerations ContentsInstallation General50PEC Physical Data Water OUT OUTCondensate A50-833522.2 OD WaterA50-8337 A50-8338Damper Opening A50-833950PEC18 Bottom Return Cabinet Dimensions Right Hand Piping 50PEC09-15 Bottom Return Cabinet Dimensions Left Hand Piping 50PEC18 Bottom Return Cabinet Dimensions Left Hand Piping 50PEC09-15 Front Return Cabinet Dimensions Right Hand Piping 50PEC18 Front Return Cabinet Dimensions Right Hand Piping A50-8345 50PEC09-15 Front Return Cabinet Dimensions Left Hand Piping50PEC18 Front Return Cabinet Dimensions Left Hand Piping A50-8347 Optional Autoflow Valve Motorized 50PEC09-15 Chassis Dimensions Front ReturnOptional Disconnect Box Autoflow Optional FusedOptional Motorized Water Valve Optional Autoflow50PEC18 Chassis Dimensions Front Return Mount Unit Wire Electrical Connections09-18 A50-8452A50-8327.eps Sensor, Water Coil Freeze Protection A50-8328Night Low Limit Switch A50-8329Return Air Sensor Blower Motor Wiring NLL PremierLink Controller Applications with Complete C Control A50-8355 8354 A50LWT 8353 Wshp Open Control A50-8380Electrical Data 50PEC Units Wire Low Voltage ConnectionsA50-7467tf A50-8441Recommended Thermostat Wire Sizes Field-Supplied Sensors for Wshp Open ControllerSPT Sensors Rnet Wiring Specifications Install Supply and Return PipingRnet Wiring A50-8443Temporary Connection for Flushing System Piping PRE-START-UPMin Ambient Air Rated Ambient Air Max Ambient Air Air and Water LimitsMin Entering Air Rated Entering Air, dry bulb/wet bulb Max Entering Air, dry bulb/wet bulbWater Quality Guidelines Deluxe D Control Jumper Settings See , 20, Complete C Control Jumper Settings See , 18,DIP Switch Block S2 Accessory 1 Relay Options Field Selectable InputsSTART-UP DIP Switch Block S2 Accessory 2 Relay OptionsUnit Start-Up/Cooling Operating LimitsBACview6 Display Interface Unit Start-Up with Wshp Open ControlsGPM Coaxial Water Pressure DropAntifreeze Percentages by Volume Approximate Fluid Volume gal Per 100 ft of PipeOperation Units with Aquazone Complete C ControlUnits with Wshp Open Multiple Protocol Page Complete C and Deluxe D Board System Test Aquazone Deluxe D Control LED Indica Complete C Control LED Code and Fault DescriptionsService Gravity Flow Method Refrigerant Charging TroubleshootingAir Coil Fan Motor Removal Replacing the Wshp Open Controller’s BatFault Heating Cooling Possible Cause Solution TroubleshootingUnit Does Not Operate Alarm Status Appendix a Wshp Open Screen ConfigurationStatus SensorMaintenance Appendix a Wshp Open Screen ConfigurationSystem Settings ConfigurationSchedule Optimal StartAppendix a Wshp Screen Open Configuration ServiceTest Point Name Password Editable Range Default Level Configuration ServiceAlarm High Alarm LimitPage Page Copyright 2009 Carrier Corporation II. START-UP 50PEC Unit START-UP ChecklistCooling Cycle Analysis Heating Cycle AnalysisA50-8453 A50-8454