CHAPTER 5
Fixture Control
Macros
The Macro parameter controls Internal Effects™ macros. These are
•Pan sweep, small to large angle
•Tile Sweep, small to large angle
•Clockwise circle, small to large
•Counterclockwise circle, small to large
With the MSpeed set at the default value of DMX
Control Function Options
The Control parameter remotely initiates various fixture operations.
Note: All of the following Control parameter settings (except for the Safe and Outrig mode options), require that the Dim channel value equals zero.
DMX Value | Control | Description | |
(dec.) | Option | ||
| |||
|
|
| |
Safe | Disables all Control setting | ||
|
|
| |
Display Off | Turns the Display off | ||
|
|
| |
Display Bright | Sets the Display to bright | ||
|
|
| |
Home | Remotely homes all the motion functions of the fixture | ||
|
|
| |
|
| Remotely deactivates the fixture. When a fixture is shut down, the | |
Shutdown | graphic engine stops, power to the motors is disabled, and the menu | ||
display reads SHUT DOWN in SHOWPIX fixtures or S/DN in StudioPix | |||
|
| fixturesIf a fixture is in shutdown mode, you must home the fixture to | |
|
| bring it back into operation. | |
|
|
| |
|
| This option applies to SHOWPIX fixtures only. For more information, | |
Outrig Mode | see Chapter 2: Setup and Configuration in the SHOWPIX User | ||
Manual. It insures uninterrupted movement of pan and tilt for fixtures | |||
|
| side mounted or in acute angular positions. | |
|
| Because this is a DMX mode, it will not persist in the fixture. | |
|
|
|
34 | StudioPix™ Pixelation Luminaire User Manual |