SSI America 7SL Display Update Time Range, Reference Accuracy, Temperature Drift, Humidity, Input

Page 27

Display Update Time

Range

1) TC type J

-100

to

1000

°C

 

500 ms

 

 

 

-150

to

1830

°F

 

The display value can be filtered

 

2) TC type K,

-100

to

1370

°C

Reference Accuracy

 

 

 

-150

to

2500

°F

 

± 0.2% fsv ±1 digit @ 25 °C and nominal

 

3) TC type T

-200

to

400

°C

 

power supply voltage.

 

 

 

-330

to

750

°F

Temperature Drift

 

4) TC type E

-100

to

800

°C

 

Less than 200 ppm/°C of full span for mV

 

 

 

-150

to

1470

°F

 

and TC ranges 1, 2, 4, 5, 9, 14 (CJ

 

5) TC type N

-100

to

1400

°C

 

excluded).

 

 

 

-150

to

2550

°F

 

Less than 300 ppm/°C of full span for mA/

 

6) TC type S

-50

to

1760

°C

 

V and TC ranges 11, 12, 13 (CJ excluded)

 

 

 

-60

to

3200

°F

 

Less than 400 ppm/°C of full span for RTD

 

7) TC type R

-50

to

1760

°C

 

range 15 and TC range 10 (CJ excluded).

 

 

 

-60

to

3200

°F

 

Less than 500 ppm/°C of full span for TC

 

8) TC type B

0

to

1820

°C

 

ranges 3, 6, 7 (CJ excluded).

 

 

 

32

to

3300

°F

 

Less than 600 ppm/°C of full span for TC

 

9) TC type L [DIN43710-1977]

 

 

 

range 8.

 

 

 

-100

to

900

°C

 

NOTE: Precision and drift guaranteed

 

 

 

-150

to

1650

°F

 

(for T>300°C/570°F).

 

10)

TC type U [DIN43710-1977]

 

Reference Junction Drift

 

 

 

-200

to

600

°C

 

0.1 °C/°C

 

 

 

-330

to

1110

°F

Common Mode Rejection Ratio

 

11)

TC type G [W - W, 26% Re]

 

 

120 dB @ 50/60 Hz

 

 

 

0

to

2300

°C

Normal Mode Rejection Ratio

 

 

 

0

to

4170

°F

 

60 dB @ 50/60 Hz

 

12)

TC type D [W, 3% Re - W, 25% Re]

Ambient Temperature

 

 

 

0

to

2300

°C

 

0 to 50 °C

 

 

 

0

to

4170

°F

Storage Temperature

 

13)

TC type C

0

to

2300

°C

 

-20 to 70 °C

 

 

 

0

to

4170

°F

Humidity

Maximum of 85% RH non condensing

 

14)

TC type Platinel II

 

 

 

Input

Thermocouple (J, K, T, E, N, S, R, B, L, U,

 

 

 

-100

to

1400

°C

 

G, D, C, Platinel II), RTD Pt100, mVdc,

 

 

 

-150

to

2550

°F

 

Vdc, mAdc. The type of inputs are key-

 

15)

RTD PT100

-200

to

850

°C

 

board and jumper selectable.

 

 

 

-330

to

1560

°F

 

 

 

16)

Linear

0

to

20

mA

 

 

 

17)

Linear

0

to

60

mV

 

 

 

18)

Linear

0

to

5

V

 

 

 

19)

Linear

0

to

10

V

 

 

2 7

 

 

 

 

 

 

7sl-5-00.p65

27

9/17/02, 2:43 PM

Image 27
Contents Model 7SL HIGH/LOW Limitrol 16 DIN, Four Digit HIGH/LOW Limitrol Guide to simple set-up CongratulationsUSE Wire Suitable For 75C Minimum Table of ContentsMounting Requirements Dimensions and Panel Cutout Wiring Guidelines Terminal LayoutMeasuring Inputs TC Input Logic Input Linear InputRTD Input RTD7sl-1-00.p65 17/02, 239 PM OUT Relay OutputsCommon Serial InterfacePower Line and grounding Power SupplyPreliminary Hardware Settings Limitrol without RS-485 Limitrol with RS-485Configuration Procedure Configuration KEY FunctionsR1 = Input Type and Range Value R2 = Decimal Point Position R5 = Offset AdjustmentR7 = Alarm Action on Fault C2 = Acknowledgment ModeControl Output Function C3 = Reset at Power-up C4 = Reset MemoryP2 = Alarm configuration OFF = P3 = Alarm ActionAlarm Standby Function = Safety LockT1 = Timeout Selection tn10 = 10 second timeout Reset Operating ModeNormal Display Mode IndicatorsKey Functions in Normal Display Mode Parameter Display ModeKey Functions in Parameter Display Mode Operating Parameters Dealing with Error Messages Error MessagesError Messages Error ListLoading Default Configuration Parameters Default ParametersLoading Default Operating Parameters Default Operating Parameters ListPara Default Configuration Parameter ListSpecifications Normal Mode Rejection Ratio Display Update Time RangeTemperature Drift Common Mode Rejection RatioType of Alarm Acknowledgment ModePower-Up Mode Alarm FunctionENV50140 ReferencesCEI 70-1 IEC NemaCalibration Procedure General GuidelinesCalibration Parameters Entering Calibration Values ProcedureTH TC Input Final Scale Value TC Input CheckPL RTD Input Initial Scale Value PH RTD Input Final Scale ValueRTD Check RJ. Cold Junction Compensation CheckVolt Input Check AH Current Input Final Scale ValueCurrent Input Check NH 5 Volt Input Final Scale ValueUH 10 Volt Input Final Scale Value UL 10 Volt Input Initial Scale ValueMaintenance Manual Part No 7SL