SSI America 7SL instruction manual 16 DIN, Four Digit HIGH/LOW Limitrol

Page 2

1/16 DIN, FOUR DIGIT HIGH/LOW LIMITROL

MODEL: 0 7 S L

- 9 1

- 0 0 0 - 0 - 0 0

Field No. 1 2 3 4

5 6 7

8 9 10 11 12 13 14 15

Fields 1 through 4. BASE

07SL - Limitrol (High/Low Limit – shipped as High Limit)

Field 5. INPUT

9 - TC types J, K, T, E, N, S, R, B, L, U, G, D, C and Platinel II; and Pt 100 RTD;

0 to 20 mAdc and 4 to 20 mAdc;

0 to 60 mVdc and 12 to 60 mVdc;

0 to 5 Vdc or 1 to 5 Vdc;

0 to 10 Vdc or 2 to 10 Vdc

Note: All inputs are factory calibrated and selectable by jumper. Factory set at Type J.

Field 6. OUTPUT (High/Low Limit)

1 - Relay (Form C)

Fields 7, 8. ALARMS, OPTIONS

00 - None

10 - One alarm – Relay Form A

11 - One alarm – Relay Form A, plus RS485 and one logic input

Note: when code 11 is specified, instrument length is 122 mm.

Field 9. POWER SUPPLY

3 - 100 to 240 Vac

5 - 24 Vac/Vdc

Fields 10 through 15. RESERVED

2

7sl-0-00.p65

2

9/17/02, 2:35 PM

Image 2
Contents Model 7SL HIGH/LOW Limitrol 16 DIN, Four Digit HIGH/LOW Limitrol Congratulations Guide to simple set-upTable of Contents USE Wire Suitable For 75C MinimumMounting Requirements Dimensions and Panel Cutout Measuring Inputs TC Input Wiring GuidelinesTerminal Layout RTD Linear InputRTD Input Logic Input7sl-1-00.p65 17/02, 239 PM Relay Outputs OUTSerial Interface CommonPreliminary Hardware Settings Power Line and groundingPower Supply Limitrol with RS-485 Limitrol without RS-485Configuration KEY Functions Configuration ProcedureC2 = Acknowledgment Mode R5 = Offset AdjustmentR7 = Alarm Action on Fault R1 = Input Type and Range Value R2 = Decimal Point PositionControl Output Function P2 = Alarm configuration C3 = Reset at Power-upC4 = Reset Memory = Safety Lock P3 = Alarm ActionAlarm Standby Function OFF =T1 = Timeout Selection tn10 = 10 second timeout Indicators Operating ModeNormal Display Mode ResetKey Functions in Parameter Display Mode Key Functions in Normal Display ModeParameter Display Mode Operating Parameters Error List Error MessagesError Messages Dealing with Error MessagesDefault Operating Parameters List Default ParametersLoading Default Operating Parameters Loading Default Configuration ParametersDefault Configuration Parameter List ParaSpecifications Common Mode Rejection Ratio Display Update Time RangeTemperature Drift Normal Mode Rejection RatioAlarm Function Acknowledgment ModePower-Up Mode Type of AlarmNema ReferencesCEI 70-1 IEC ENV50140Calibration Parameters Calibration ProcedureGeneral Guidelines TC Input Check ProcedureTH TC Input Final Scale Value Entering Calibration ValuesRJ. Cold Junction Compensation Check PH RTD Input Final Scale ValueRTD Check PL RTD Input Initial Scale ValueNH 5 Volt Input Final Scale Value AH Current Input Final Scale ValueCurrent Input Check Volt Input CheckUL 10 Volt Input Initial Scale Value UH 10 Volt Input Final Scale ValueMaintenance Manual Part No 7SL