SSI America 7SL instruction manual References, CEI 70-1 IEC, Nema, ENV50140

Page 29

References

 

UL 94

Tests for flammability of plastic materials

 

for pans in devices and appliances

CEI 70-1 (IEC 529)

 

Degrees of protection provided by enclo-

 

sures (IP Code)

NEMA 250-1991

 

Enclosures for equipment (1000 Volts

 

maximum)

DIN 43700

Measurements and control instruments

 

for panel mounting. Nominal front and

 

cut-out dimensions.

EN 50081-2

Electromagnetic compatibility - Generic

 

emission standard - Part 2. Industrial

 

environment.

EN 55011

Limits and methods of measurement of

 

radio disturbance characteristics of in-

 

dustrial, scientific and medical (ISM) radio

 

frequency equipment.

EN 50082-2

Electromagnetic compatibility - Part 2 -

 

Industrial environment

ENV50140

Electromagnetic compatibility - Basic im-

munity standard -

Radiated radio - frequency electro-mag- netic field- Immunity test.

IEC 1000-4-2Electromagnetic compatibility (EMC) Part 4: Testing and measurement tech- nique. Section 2: Electrostatic discharge immunity test.

EN-61000-4-8Electromagnetic compatibility (EMC) Part 4: Testing and measurement tech- niques

Section 8: Power frequency magnetic field immunity test.

IEC 1000-4-4Electromagnetic compatibility. Part 4: Testing and measurement techniques - Section 4: Electrical fast transient/burst immunity test.

ENV50141 Electromagnetic compatibility - Basic im- munity standard - Conducted disturbances induced by radio-frequency fields - Immu- nity test.

DIN 43710-1977

Thermocouples - Reference table.

IEC 584-1Thermocouples - Part 1 - Reference table. DIN 43760 Thermometer Reference table.

2 9

7sl-5-00.p65

29

9/17/02, 2:43 PM

Image 29 Contents
Model 7SL HIGH/LOW Limitrol 16 DIN, Four Digit HIGH/LOW Limitrol Guide to simple set-up CongratulationsUSE Wire Suitable For 75C Minimum Table of ContentsMounting Requirements Dimensions and Panel Cutout Measuring Inputs TC Input Wiring GuidelinesTerminal Layout RTD Input Linear InputRTD Logic Input7sl-1-00.p65 17/02, 239 PM OUT Relay OutputsCommon Serial InterfacePreliminary Hardware Settings Power Line and groundingPower Supply Limitrol without RS-485 Limitrol with RS-485Configuration Procedure Configuration KEY FunctionsR7 = Alarm Action on Fault R5 = Offset AdjustmentC2 = Acknowledgment Mode R1 = Input Type and Range Value R2 = Decimal Point PositionControl Output Function P2 = Alarm configuration C3 = Reset at Power-upC4 = Reset Memory Alarm Standby Function P3 = Alarm Action= Safety Lock OFF =T1 = Timeout Selection tn10 = 10 second timeout Normal Display Mode Operating ModeIndicators ResetKey Functions in Parameter Display Mode Key Functions in Normal Display ModeParameter Display Mode Operating Parameters Error Messages Error MessagesError List Dealing with Error MessagesLoading Default Operating Parameters Default ParametersDefault Operating Parameters List Loading Default Configuration ParametersPara Default Configuration Parameter ListSpecifications Temperature Drift Display Update Time RangeCommon Mode Rejection Ratio Normal Mode Rejection RatioPower-Up Mode Acknowledgment ModeAlarm Function Type of AlarmCEI 70-1 IEC ReferencesNema ENV50140Calibration Parameters Calibration ProcedureGeneral Guidelines TH TC Input Final Scale Value ProcedureTC Input Check Entering Calibration ValuesRTD Check PH RTD Input Final Scale ValueRJ. Cold Junction Compensation Check PL RTD Input Initial Scale ValueCurrent Input Check AH Current Input Final Scale ValueNH 5 Volt Input Final Scale Value Volt Input CheckUH 10 Volt Input Final Scale Value UL 10 Volt Input Initial Scale ValueMaintenance Manual Part No 7SL