Grounding Instructions
This machine MUST be grounded. In the event of certain malfunctions or breakdowns, grounding reduces the risk of electric shock by providing a path of least resistance for electric current.
The plug specified under "Circuit Requirements" on the previous page has a grounding prong that must be attached to the
G0453 | GROUNDED |
| |
| Current Carrying Prongs |
| Grounding Prong |
Figure 3. Typical 6-20 plug and receptacle.
G0454 | |
| LOCKING |
| RECEPTACLE |
| Grounding Prong |
| is Hooked |
| |
| LOCKING |
| PLUG |
Current Carrying Prongs
Figure 4. Typical L6-30 plug and receptacle.
NOTICE
No adapter is available or should be used with this machine. If the machine must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel; and after reconnection, the machine must com- ply with all local codes and ordinances.
Serious injury could occur if you connect the machine to power before completing the setup process. DO NOT connect to power until instructed later in this manual.
Improper connection of the
Check with a qualified electrician or service per- sonnel if you do not understand these grounding requirements, or if you are in doubt about whether the tool is properly grounded. If you ever notice that a cord or plug is damaged or worn, discon- nect it from power, and immediately replace it with a new one.
Extension Cords
We do not recommend using an extension cord with this machine. If you must use an extension cord, only use it if absolutely necessary and only on a temporary basis.
Extension cords cause voltage drop, which may damage electrical components and shorten motor life. Voltage drop increases as the extension cord size gets longer and the gauge size gets smaller (higher gauge numbers indicate smaller sizes).
Any extension cord used with this machine must contain a ground wire, match the required plug and receptacle, and meet the following require- ments:
G0453 Minimum Gauge Size | 12 AWG |
G0454 Minimum Gauge Size | 10 AWG |
Maximum Length (Shorter is Better) | 50 ft. |
G0453/G0454 (Mfg. Since 3/08) |