4-6. Robot Auto-Calibration Sample Programs
.It is critical to make certain that NO start power, start conditions,
Actual Motoman Welder Condition File
<Welding Current Output Char.>
NO. | REF (V) | MEASURE (A) |
01 | 0.01 | 1 |
02 | 7.00 | 500 |
03 | 13.99 | 999 |
04 | 0.00 | 000 |
<Welding Voltage Output Char.> | ||
NO. | REF (V) | MEASURE (V) |
01 | 0.14 | 0.5 |
02 | 7.00 | 25.0 |
03 | 14.00 | 50.0 |
04 |
|
|
Sample | ||
0000 | NOP |
|
0001 | Mov J |
|
0002 | AWELD 1.40 (AWELD direct input of 1.40Volts = 100 ipm) | |
0003 | VWELD 2.80 | (VWELD direct input of 2.80Volts = 10.0 volts) |
0004 | Arcon |
|
0005 | Timer T=10.00 |
|
0006 | Arcof |
|
0007 | AWELD 14.00 (AWELD direct input of 14.00Volts = 1000 ipm) | |
0008 | VWELD 12.32 (VWELD direct input of 12.32Volts = 44.0 volts) | |
0009 | Arcon |
|
0010 | Timer T=10.00 |
|
0011 | Arcof |
|
0012 | End |
|