4-1 . Operational Terms (Continued)

Start

Provides voltage/arc adjust, wire feed rate, and time value for modified arc starts (only available on Auto Axcess

 

models in the Arc On and Analog input or the Arc On and No Analog input modes, and can only be set with the

 

optional PDA with File Management software).

Weld

Sequence function that allows for a timed weld operation [(0 to 999 seconds) only available on Auto Axcess

 

models in the Arc On and Analog input or the Arc On and No Analog input modes, and can only be set with the

 

optional PDA with File Management software].

Crater

Allows setting of voltage/arc adjust, wire feed rate, and time value for arc ends (only available on Auto Axcess

 

models in the Arc On and Analog input or the Arc On and No Analog input modes, and can only be set with the

 

optional PDA with File Management software).

Postflow

Setting a time value for gas flow after arc end (only available on Auto Axcess models in the Arc On and Analog

 

input or the Arc On and No Analog input modes, and can only be set with the optional PDA with File Manage-

 

ment software).

Retract

Sequence function that allows the wire to move back towards the contact tip when a welding operation is

 

completed. Setting is both speed (IPM) and time (sec), (only available on Auto Axcess models in the Arc On

 

and Analog input or the Arc On and No Analog input modes, and can only be set with the optional PDA with File

 

Management software).

Auto Thread

Method of jogging wire without holding jog or trigger switch. Pressing Jog and Retract simultaneously will

 

automatically feed wire. Default setting is 72 inches at a feed rate of 700 ipm. Pressing jog, purge, or trigger

 

switch will terminate the auto-threading feature. These values can be changed using a PDA with File

 

Management/WaveWriter software.

OM-201 540 Page 23

Image 27
Contents File Advanced Manufacturing Systems OM-201 540KProcesses DescriptionFrom Miller to You Table of Contents Warranty HOT Parts can cause severe burns Symbol UsageArc Welding Hazards Electric Shock can killFlying Metal or Dirt can injure eyes Fumes and Gases can be hazardousARC Rays can burn eyes and skin Welding can cause fire or explosionMoving Parts can cause injury Welding Wire can cause injuryFire or Explosion hazard Falling Unit can cause injuryAbout Implanted Medical Devices Principal Safety StandardsCalifornia Proposition 65 Warnings EMF InformationUNE Décharge Électrique peut entraîner la mort Symboles utilisésDES Pièces Chaudes peuvent provoquer des brûlures graves LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un in cendie ou une explosion LA Chute DE L’APPAREIL peut blesser LE Bruit peut endommager l’ouïeLES Bouteilles peuvent exploser si elles sont endommagées Risque D’INCENDIE OU D’EXPLOProposition californienne 65 Avertissements LES Fils DE Soudage peuvent provoquer des blessuresLE Soudage À L’ARC risque de provoquer des interférences Principales normes de sécurité Information EMFEn ce qui concerne les implants médicaux OM-201 540 − Installation SpecificationsDimensions And Weight Overheating Duty Cycle And OverheatingVolt-Ampere Curves 100% Duty Cycle At 675 AmperesDo not stack units. Beware of tipping Connection DiagramSelecting a Location Movement Do not move or operate TippingRear Panel Receptacles And Supplementary Protectors Incorrect Installation Connecting To Weld TerminalsSelecting Weld Cable Sizes Socket Information Peripheral Receptacle FunctionsMotor Control Receptacle Functions Normal Operating Electrical Service GuideHz Three Phase Input Voltage Input Amperes At Rated Output Connecting Input Power Welding Power Source Input Power Connections Disconnect Device Input Power Connections Program No Output a Output B Output C Remote Program SettingTouch Sensor Operation Remote Program SelectOperational Terms − OperationPostflow StartWeld CraterGas Type LED Wire Type LEDFront Panel Controls See Section Process LEDSTL Xxxx Robot Type Front Panel SwitchesRobot Abbreviations Manufacturer Robot AbbreviationRobot Calibration Mode Schedule100 IPM 1000 IPM Robot Auto-Calibration Sample Programs Actual Motoman Welder Condition FileSample Auto-Calibration Routine For Motoman Robot Sample Auto-Calibration Routine For Fanuc Robot Sample Auto-Calibration Routine For ABB RobotWeld Data Accu-pulse Reset ModePulse Mild Steel− Maintenance Routine MaintenanceBlowing Out Inside Of Unit Exploding Parts can cause injury − Safety Precautions for ServicingShock Hazard from testing Servicing HazardsCalifornia Proposition 65 Warnings Set Value Mode − TroubleshootingDiagnostics Indicates an over On errorIndicates a trigger closed error Indicates RMD demo is doneRemoving Cover and Measuring Input Capacitor Voltage Process Control Module PC4 Diagnostic LED’s Diagnostic LED’s On Process Control Module PC4Status Diagnosis Diagnostic LED’s On Wire Feed Module PC6 Diagnostic LED’s On User Interface Module PC7 User Interface Module PC7 Diagnostic LED’sAutomation Interface Module PC9 Diagnostic LED’s LED33LED32 Diagnostic LED’s On Automation Interface Module PC9 Input signal off for aux. relay energized Input signal on from relay K6 for arc detectedInput signal off from relay K6 for no arc detected Input signal on for aux. relay energizedCircuit board is operating normally Network And Module Status LED’s Network Status LED’sModule Status LED’s RedTrouble Remedy TroubleshootingCircuit Diagram For Welding Power Source 1 − Electrical Diagrams198 992-G Part 1 Circuit Diagram For Welding Power Source 2 198 992-G Part 2 Circuit Diagram For 72 Pin Robot Interface 219 266-C Circuit Diagram For Peripheral/Motor Interface 219 267-B − Parts List 16 − Fig− Fig Windtunnel Assembly LH And RH Windtunnel Assembly LH And RH -1Item Top Tray Assembly Rear Panel Assembly Front Panel Assembly Description Quantity Page Page Service Your distributor also givesSupport Your distributor and/or equipment manufacturer’s To locate a Distributor or Service Agency visitMiller Electric Mfg. Co For assistance in filing or settling claims, contact