Table 4-2. Robot Abbreviations

 

 

 

Manufacturer

 

Robot Abbreviation

 

 

 

ABB

 

ABB

 

 

 

Fanuc

 

FANU

 

 

 

Daihen

 

DAHN

 

 

 

Kawasaki

 

KAWA

 

 

 

Kuka

 

KUKA

 

 

 

Comau

 

COMU

 

 

 

Hitachi

 

HCHI

 

 

 

Nachi

 

NCHI

 

 

 

Panasonic

 

PANA

 

 

 

Motorman

 

MOTO

 

 

 

Robot Adapter

 

DTEC

 

 

 

Detect Disabled

 

OFF

 

 

 

None

 

Robt DTEC

 

 

 

4-4. Front Panel Switches

6

3

1

4

8

5

9

1Power Switch Turns unit On or Off.

The power-up sequence may last up to 30 seconds before the unit is ready to weld. During power-up, the front panel will display messages indicating the status of the unit. The first message is:

NET

WAIT

NET WAIT is an abbreviation for ”network updating” and means the internal control network is powering up. The next message is

XXXX(Robot Type)

XXXXidentifies the robot adapter being used as identified by the unit (see Table 4-2for a list of robot adapters that could be displayed). To ensure proper operation of the system, verify the robot displayed corresponds to the actual robot being used. The final message is

2

AUTO 675

AUTO 675 indicates the software being loaded.

2 Contactor LED

Contactor LED illuminates when weld output is energized.

3 Purge Push Button

Press button to purge gas line.

4 Gas LED

Gas LED illuminates when Purge push button is pressed.

5Jog Push Button Press button to jog wire.

7

Ref. 802 914-A

6 Wirefeed LED

Wirefeed LED illuminates when wire feeds or retracts.

7 Retract Push Button

Press button to retract wire. Wirefeed LED illuminates when Retract push button is pressed.

Auto-Threading feature is activated by pressing the Jog and Retract buttons simultaneously. Pressing the Jog, Purge, or trigger switch will turn off the Auto-Threading feature.

8PDA Port

9PC Port

OM-201 540 Page 26

Image 30
Contents Description OM-201 540KProcesses File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Warranty Electric Shock can kill Symbol UsageArc Welding Hazards HOT Parts can cause severe burnsWelding can cause fire or explosion Fumes and Gases can be hazardousARC Rays can burn eyes and skin Flying Metal or Dirt can injure eyesFalling Unit can cause injury Welding Wire can cause injuryFire or Explosion hazard Moving Parts can cause injuryEMF Information Principal Safety StandardsCalifornia Proposition 65 Warnings About Implanted Medical DevicesSymboles utilisés UNE Décharge Électrique peut entraîner la mortDES Pièces Chaudes peuvent provoquer des brûlures graves LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un in cendie ou une explosion Risque D’INCENDIE OU D’EXPLO LE Bruit peut endommager l’ouïeLES Bouteilles peuvent exploser si elles sont endommagées LA Chute DE L’APPAREIL peut blesserProposition californienne 65 Avertissements LES Fils DE Soudage peuvent provoquer des blessuresLE Soudage À L’ARC risque de provoquer des interférences Principales normes de sécurité Information EMFEn ce qui concerne les implants médicaux OM-201 540 − Installation SpecificationsDimensions And Weight 100% Duty Cycle At 675 Amperes Duty Cycle And OverheatingVolt-Ampere Curves OverheatingMovement Do not move or operate Tipping Connection DiagramSelecting a Location Do not stack units. Beware of tippingRear Panel Receptacles And Supplementary Protectors Connecting To Weld Terminals Incorrect InstallationSelecting Weld Cable Sizes Peripheral Receptacle Functions Socket InformationMotor Control Receptacle Functions Input Amperes At Rated Output Electrical Service GuideHz Three Phase Input Voltage Normal OperatingConnecting Input Power Welding Power Source Input Power ConnectionsDisconnect Device Input Power Connections Remote Program Select Remote Program SettingTouch Sensor Operation Program No Output a Output B Output C− Operation Operational TermsCrater StartWeld PostflowProcess LED Wire Type LEDFront Panel Controls See Section Gas Type LEDSTL Manufacturer Robot Abbreviation Front Panel SwitchesRobot Abbreviations Xxxx Robot TypeRobot Calibration Mode Schedule100 IPM 1000 IPM Robot Auto-Calibration Sample Programs Actual Motoman Welder Condition FileSample Auto-Calibration Routine For Motoman Robot Sample Auto-Calibration Routine For Fanuc Robot Sample Auto-Calibration Routine For ABB RobotWeld Data Mild Steel Reset ModePulse Accu-pulse− Maintenance Routine MaintenanceBlowing Out Inside Of Unit Servicing Hazards − Safety Precautions for ServicingShock Hazard from testing Exploding Parts can cause injuryCalifornia Proposition 65 Warnings − Troubleshooting Set Value ModeDiagnostics Indicates RMD demo is done On errorIndicates a trigger closed error Indicates an overRemoving Cover and Measuring Input Capacitor Voltage Process Control Module PC4 Diagnostic LED’s Diagnostic LED’s On Process Control Module PC4Status Diagnosis Diagnostic LED’s On Wire Feed Module PC6 User Interface Module PC7 Diagnostic LED’s Diagnostic LED’s On User Interface Module PC7Automation Interface Module PC9 Diagnostic LED’s LED33LED32 Diagnostic LED’s On Automation Interface Module PC9 Input signal on for aux. relay energized Input signal on from relay K6 for arc detectedInput signal off from relay K6 for no arc detected Input signal off for aux. relay energizedRed Network And Module Status LED’s Network Status LED’sModule Status LED’s Circuit board is operating normallyTroubleshooting Trouble Remedy− Electrical Diagrams Circuit Diagram For Welding Power Source 1198 992-G Part 1 Circuit Diagram For Welding Power Source 2 198 992-G Part 2 Circuit Diagram For 72 Pin Robot Interface 219 266-C Circuit Diagram For Peripheral/Motor Interface 219 267-B − Parts List 16 − Fig− Fig Windtunnel Assembly LH And RH Windtunnel Assembly LH And RH -1Item Top Tray Assembly Rear Panel Assembly Front Panel Assembly Description Quantity Page Page Service Your distributor also givesSupport For assistance in filing or settling claims, contact To locate a Distributor or Service Agency visitMiller Electric Mfg. Co Your distributor and/or equipment manufacturer’s