Sanyo C3682, C3082 service manual Cooling Capacity, Indoor

Page 22

< Cooling Capacity >

RATING CAPACITY:

30,600 BTU/h

 

AIR FLOW RATE:

630 CFM

INDOOR

 

 

 

 

OUTDOOR

 

 

ENT. TEMP. oF (oC)

 

 

AMBIENT TEMP. oF (oC)

 

 

W.B.

D.B.

 

65

75

85

95

105

115

 

 

 

 

(18.3)

(23.9)

(29.4)

(35.0)

(40.6)

(46.1)

 

 

 

TC

30,650

29,970

29,190

28,600

24,890

17,310

 

72

(22.2)

SHC

21,390

21,020

20,660

20,290

18,330

14,660

59

76

(24.4)

SHC

23,710

23,350

22,980

22,610

20,660

16,990

(15.0)

80

(26.7)

SHC

26,280

25,790

25,430

25,060

23,100

17,310

 

84

(28.9)

SHC

28,610

28,240

27,750

27,380

24,890

17,310

 

88

(31.1)

SHC

30,650

29,970

29,190

28,600

24,890

17,310

 

 

 

TC

31,580

30,910

30,160

29,630

25,270

17,560

 

72

(22.2)

SHC

18,330

17,970

17,600

17,360

15,150

11,730

63

76

(24.4)

SHC

20,660

20,290

19,920

19,680

17,480

14,050

(17.2)

80

(26.7)

SHC

23,100

22,740

22,370

22,120

20,050

16,500

 

84

(28.9)

SHC

25,430

25,060

24,690

24,450

22,370

17,560

 

88

(31.1)

SHC

27,750

27,510

27,020

26,770

24,690

17,560

 

 

 

TC

32,420

31,780

31,050

#

30,600

25,550

17,760

 

72

(22.2)

SHC

15,150

14,790

14,420

14,300

12,100

8,920

67

76

(24.4)

SHC

17,480

17,110

16,870

16,620

14,420

11,240

(19.4)

80

(26.7)

SHC

19,920

19,560

19,310

19,070

16,870

13,690

 

84

(28.9)

SHC

22,250

22,000

21,640

21,390

19,190

16,010

 

88

(31.1)

SHC

24,570

24,330

23,960

23,710

21,510

17,760

 

 

 

TC

33,130

32,540

31,840

31,490

25,710

17,880

 

72

(22.2)

SHC

11,730

11,480

11,120

11,000

8,670

5,860

71

76

(24.4)

SHC

14,050

13,810

13,440

13,320

11,120

8,310

(21.7)

80

(26.7)

SHC

16,500

16,250

15,890

15,770

13,560

10,750

 

84

(28.9)

SHC

18,820

18,580

18,330

18,210

15,890

13,070

 

88

(31.1)

SHC

21,150

20,900

20,660

20,530

18,210

15,400

 

 

 

TC

33,630

33,090

32,430

32,190

25,730

17,900

75

76

(24.4)

SHC

10,750

10,510

10,260

10,140

7,940

5,370

(23.9)

80

(26.7)

SHC

13,200

12,950

12,710

12,590

10,380

7,820

 

84

(28.9)

SHC

15,520

15,280

15,030

15,030

12,710

10,140

 

88

(31.1)

SHC

17,840

17,720

17,480

17,360

15,030

12,590

 

 

 

TC : Total

Cooling

Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) D.B. / 67 °F (19.4 °C) W.B.

:Outdoor Ambient Temp. 95 °F (35 °C) D.B.

2.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.

22

Image 22
Contents Indoor Model No. Product Code No Destination North AmericaSafety Precautions Prohibit Table of Contents Checking Electrical Components Operating Range Indoor Air Intake Temp Outdoor Air Intake TempKS3082 SpecificationsUnit Specifications C3082208V KS3682 C368221.9 Major Component Specifications Indoor UnitCB-KS3682 Microprocessor 250V 3A Board Outdoor UnitOutdoor Unit C3082 CompressorOutdoor Unit C3682 Other Component Specifications Dimensional Data Indoor Unit KS3082Inchmm Refrigerant Flow Diagram Refrigerant Flow DiagramOperating current performance chart Temperature ChartsLow pressure performance chart Indoor discharge air performance chartWide Cooling Capacity Indoor OutdoorCooling Capacity Indoor34,000 BTU/h Power Supply 230V Single Phase 60Hz Cooling Capacity IndoorCooling Vertical distance ft Air Throw Distance ChartsRoom air temp F 26.7C Fan speed High Horizontal distance ft Air C3082 Voltage230V Cooling Electrical CharacteristicsElectrical Data Voltage208V CoolingC3682 Voltage230V Cooling KS3082 KS3682 Electric Wiring Diagrams8FA2-5250-70400-3 8FA2-5250-71800 Noise Filter P.C.BOARDOperation Functions FunctionsEmergency operation Timer backup Lamp colorsNoise Reducing Control Outdoor Unit Switching Procedure to Noise Reducing ControlOperation Sound Description of function Maximum Current Value Change ProcedureMaximum Current Value Change Function C3682Protective Functions Compressor discharge temperature controlCompressor discharge temperature FC Freeze preventionPrecautions before Performing Inspection or Repair TroubleshootingMethod of Self-Diagnostics Self-diagnostics Lamps Replace the controller NormalReplace the circuit board or the fuse Checking the Indoor and Outdoor Units Using the TEST/T-RUN terminalsChecking the indoor unit Control Check items unit operation Off Blinking Illuminated Serial Communication Error Identification ProcedureAlarm Code E05 Before the OperationTerminal board Outdoor Unit Alarm Code E07/P04/P05/P20/P27 Trouble Diagnosis of Fan Motor Indoor Fan MotorOutdoor Fan Motor Electromagnetic interference Noise Malfunction and Electromagnetic InterferenceNoise malfunction Locations most susceptible to noise Trouble CorrectionMeasurement of Insulation Resistance Power Supply CordChecking Electrical Components Measurement of Insulation Resistance for Electrical PartsChecking Continuity of Fuse on PCB Assy What is New Refrigerant R410A? Refrigerant R410A Special Precautions When Servicing UnitCharacteristics of New Refrigerant R410A CharacteristicsChecklist before Servicing Tubing Installation Procedures Tools Specifically for R410AProcedure for Replacing Compressor Case of Compressor MalfunctionDamage to the compressor Never charge a large amountUnit. This may cause ExampleWelding leaking points Case Refrigerant is LeakingRecharging Retro-Fitting Existing Systems When Tubes are ExtendedCharging Additional Refrigerant Use of Existing UnitsOI-852-6-4181-150-00-0 Mode D’EMPLOI Pub. OI-85264181150000 SanyoFeatures ContentsSafety Instructions Alert SymbolsInstallation Location Product InformationNames of Parts Unit Display and Operation ButtonRemote Control Unit Display SymbolsRemote Control Unit Mode selector button HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp High Power buttonACL button Using the Remote Control UnitAir conditioner Indoor unit Receiver Remote control unit 16 mmAutomatic fan speed Operation with the Remote Control UnitManual fan speed Cooling and DRY Mode Cooling Mode Unoccupied Indication StatusHow it works? Setting the TimerSpecial Remarks Clicking sound is heard from the air conditionerTo cancel a timer program 1030 pm 710 am 1100 am Present timeTips for Energy Saving Using the 1-HOUR OFF TimerAdjusting the Airflow Direction Do notCare and Cleaning Cleaning the main unit and remote control unit How to install the air clean filterHow to clean the air clean filter Removing and remounting the front panelOperating Range TroubleshootingWired Remote Controller Trouble Possible Cause RemedyAppendix B Installation Instructions Installation Instructions ContentsPlease Read Before Starting General Tools Required for Installation not suppliedAccessories Supplied with Unit Table Optional Copper Tubing KitInstallation Site Selection Additional Materials Required for InstallationSolid base must not cover the hole of the bottom plate Precautions for Installation in a Snowy Area Countermeasures against snow and windUnit inch Required space around the outdoor unit Installation with intakes facing outletsFront and both sides must remain open Unit Multiple-unit installation 2 or more units Top is open Single-unit installationObstacle to the front of unit Installation in front-rear rows Obstacles to the front and rear of unitRemove the Rear Panel from the Unit How to Install the Indoor UnitTrical wiring or conduits are Make a HoleIf Block, Brick, Concrete or Similar Type Wall Install the Rear Panel on the WallIf Wooden Wall Hole DiaHow to remove the grille Removing and Installing the GrilleHow to replace the grille Wiring Instructions General precautions on wiring Shape the Indoor Side TubingC3682 Wire Size and LengthModel Fuse or CircuitWiring Instructions for Inter-unit Connections For Outdoor Unit For solid core wiring or F-cable How to connect wiring to the terminal For Indoor UnitFor stranded wiring Mounting Right-side tubingLeft-side tubing Switching drain hose and drain capDrain cap To unmount indoor unit Do not supply power toTubing and wiring to the out Frame Fastening MethodWiring Instructions for the Outdoor Unit How to Install the Outdoor UnitFirst refer to . Installation Site Selection Routing the Tubing and WiringUse of the Flaring Method Flaring Procedure with a Flare ToolRefrigerant Tubing If the special R410A flare tool is usedInsulation of Refrigerant Tubing Connecting Tubing between Indoor and Outdoor UnitsFinishing the Installation Taping the TubesAir Purging Hex wrench before Be sure to completely insertAttempting to turn the valve How to Test Run the Air Conditioner Basic Functions of the Service Valves Pump DownService Valve Connections Remote Control Unit Installation PositionAddress Switch Address Setting of the Remote Control Unit