Indoor Unit | KS3682 |
|
|
|
| ||
Outdoor Unit | C3682 |
|
|
|
| ||
(1) Voltage:230V |
|
|
|
|
|
| |
Cooling |
|
|
|
|
|
| < 230V > |
|
|
|
|
| Indoor Unit | Outdoor Unit | Complete Unit |
|
|
|
|
| Fan Motor | Fan Motor + Compressor | |
|
|
|
|
|
| ||
Performance at |
|
|
|
| 230V |
| |
Rating conditions |
| Running amp. | A | 0.4 | 19.6 | 20.0 | |
|
|
| Power input | W | 39 | 3,961 | 4,000 |
Rating conditions: | Indoor air temperature: | 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B. |
| ||||
|
| Outdoor air temperature: | 95°F (35°C) D.B. |
|
| ||
(2) Voltage:208V |
|
|
|
|
|
| |
Cooling |
|
|
|
|
|
| < 208V > |
|
|
|
|
| Indoor Unit | Outdoor Unit | Complete Unit |
|
|
|
|
| Fan Motor | Fan Motor + Compressor | |
|
|
|
|
|
| ||
Performance at |
|
|
|
| 208V |
| |
Rating conditions |
| Running amp. | A | 0.4 | 21.5 | 21.9 | |
|
|
| Power input | W | 39 | 3,961 | 4,000 |
Rating conditions: | Indoor air temperature: | 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B. |
| ||||
|
| Outdoor air temperature: | 95°F (35°C) D.B. |
|
|
28