Baldor mn1854 manual Encoder Color Code, 10Receiving & Installation MN1854, +5VDC

Page 21

Encoder Connections (Refer to MN1800 for wire color and lead information.)

The location for each encoder connector (Side Panel) is shown in Figure 3-4. Twisted pair shielded wire with an overall shield should be used. Figures 3-12 and 3-13 show the connections between the encoder and the encoder connector.

Figure 3-12 Differential Encoder Connections for UL Installations

Encoder

A+

A+

A–

A–

B+

B+

B–

B–

Z+

C+ (Index)

Z–

C– (Index)

+5V

+5V

Com

Com

Drain

Shell (Chassis)

Figure 3-13 Differential Encoder Connections for CE Installations

Encoder

Connection of shields to digital ground is optional.

PE

A+

A–

B+

B–

Z+

Z–

+5V Com Drain

A+

A–

B+

B–

C+ (Index)

C– (Index) +5V Com

Shell (Chassis)

Table 3-2 Encoder Color Code

Encoder

Signal

PVS100

Danaher (9–Pin D)

A+

White

Green

6

A–

Gray

Yellow

1

B+

Orange

Blue

8

B–

Red

Violet

3

Z+ (Index)

N/A

Red

9

Z– (Index)

N/A

Orange

5

+5VDC

Black

Brown

7

GND

Brown

Black

2

Inner shield

Blue

4

Outer shield

Violet

Shell

3-10Receiving & Installation

MN1854

Image 21
Contents LinStep+ Dual-Axis Microstepping Indexer/Driver Table of Contents Other Programming Samples Ii Table of Contents MN1854 Arithmetic Operands and EquationsIncrement/Decrement Variables Troubleshooting Serial Communications Problems Iv Table of Contents MN1854 Limited Warranty Section General InformationCE Compliance Could result in injury or death Product Notice Intended useCould result in damage to property On next 2General Information MN1854Connection before you first ensure that power has been Do not touch any circuit board, power device or electricalDo not apply AC power before you ensure that grounds are Voltages that are conducted to its power input terminals.Instead, we recommend using a four wire Wye Extend more than 0.2 5 into keypad assemblyPower is removed from the drive Driver should have specifications compatible to the driveSection Product Overview OverviewMotors Product Overview MN1854 Power Dissipation Section Receiving and InstallationMechanical Installation Receiving & InspectionGND 2Receiving & Installation MN1854System Grounding Ungrounded Distribution System Input Power ConditioningWire Size and Protection Devices Power Connections Power connections are shown in Figure4Receiving & Installation MN1854 Connection Locations 115VAC, 2 Axis MN1854 Receiving & InstallationTools Required 6Receiving & Installation MN1854RS-232 PC Connections 9 & 25 Pin RS-232 Cable Connections for UL InstallationsDaisy Chain Connections 8Receiving & Installation MN1854Rules for Daisy Chain Operation PC / Host DeviceOptional Opto I/O Connections Programmable I/O ConnectionsThese input connections are made at terminals 6-40 Figure Typical connection each inputEncoder Signal PVS100 Danaher 9-Pin D 10Receiving & Installation MN1854Encoder Color Code +5VDCLD9068A00 Leadwire Connection 9 pin to flying leads Motor ConnectorInterlock Intlk Ground GNDPower Off Checks Start-Up ProcedureSwitch and Potentiometer Settings Section General InformationAction Display Comments Power On ChecksMotor should now be producing torque HighReceiving & Installation MN1854 Overview Section Keypad OperationKeypad layout with the LCD display is shown in Figure F1, F2, F3Copies one program to another within the LinStep+ Decimal Point CommaAlpha Thus eliminating the need for a PC terminal connection TestTrace Output Move Shutdn RS232 EncoderPressing the Edit key displays a set of sub-menus Edit MenuEdit an existing program Save the program6Keypad Operation MN1854 Save Program? YesNoExample of Naming a Program Naming a programPress ESC. You will be prompted as shown in Figure Mine AC.3 VE2 DI1 GOEntering Characters with the Alpha Key In edit mode Use the =O keys for additional alpha characters8Keypad Operation MN1854 Submenu Setup Parameter Description of Setup Parameter Edit, Setup SubmenuPress EDIT, ↓ , List to Press EDIT, POS F3 Press YES F1 or no F3Display the number Programs stored Press ↓ to display the totalPressing Help in Menus and Sub-Menus Pressing Help in the Main MenuPressing Help In the Program Edit function Sequentially Eeprom message disappearsEnter the program number. Or, if COPY, to PAD SubmenuYou wish, you can scroll the list Program namesProcedure Format Definition Section SetupAxis One Motor Type Steper Setup MN1854Axis One Drive Res Axis One Motor DirOpen Loop Axis One ENC ModeApplication Notes Axis One Encoder RES ↑5000 cnts/in ↓Value IN-RANGE Setup WindowIN-RANGE Window PM GainMech Setup Configure Your Application MechanicsDist Vmax Accel AmaxEdit Axis One Vel Units In/sAxis One MAX Vel 500.0 in/s ↓→Configure the I/O Iuuuuuuu ←↑↓→Char Keypad Display Input Character Description Service routine program Inputs will work. See the RG command for more detailsTo summarize, when INT98CTRL=1 Reset to 1. This allows for input debounce and controllingPower-up program, if defined, will start Warm BootJog Speed InputsOUT1 Programmable Pppppppp ←↑↓→ OPTO9 Input Configure the Output StatesIiiiiiii OFFConfigure JOG Parameters Configure End of Travel Switch PolarityEnable Accel LO-VEL HI-VELConfigure Home Parameters Mode Edge SwitchOffset DIR Negative ↑SETUP↓ Configure Power-up ProgramPower Up Program PROGRAM0 Axis One Final Dir PositiveRS232C Setup Configure Serial Communications↑ Enabled ↓ Echo UNIT#Data Type Description of Display Data Type Configure Miscellaneous Setup ParametersPassword Setup General Password RulesOpratr Admin Clear Password Type Description Gives access to these menusSection Keypad Programming Keypad Program Command ListAcceleration Start Home Outputs On/Off Function Key Message to DisplayValue Units Range Keypad Programming MN1854Example AC2 DE.5 VE12 DA3 GO DA3 GO DA3 GODC Distance to Change DCn * DCn*1 * Vn*1 2* Vnt w Example Distance to ChangeExamples of DC move profiles, AC = seconds, VE=ips DC n + 10 +AC.1 VE60 DI2 GO DI1 GO DI-4 GO DE DecelerationValue Units Range N/A LP2 DI3 GO EBIF2,1 EN EB DI2 GO =26 =27 =28 =12 =13 =17 =18 =22 =23RUN Edit Copy DELExample 3-Screen Menu Program GH Start Home Set in Edit Setup Mech Accel VELValue N/A Units N/A Range N/A Go Immediate Syntax GI or GIiValue N/A Units N/A Range i=1-16 GO Go Start a Move Syntax GO or GOiAC.05 DE.05 VE50 DI5 GO VE2 AC.1 DA4,2 GP=1-400, name = any legal program name Gosub Syntax GSi and GSnameIF10 Gtpart a EB If input 1 is on and input 2 is off, jump to program Part aIFPARTS=25 GS20 EB Units RangeIV12,LENGTH LppiecesDilength Value Units N/A Range N/A Syntax LPi LP LoopSyntax MC+ MC Move Continuous Move Continuous 27 7th character, 2nd row MS27,COUNTGthome Powerup ONL,GTON EOTMain VE5 DA20 GO=0 input high. X=1 input low grounded = starting output number=anything else ignore input changes OT4,1 Turn on Output OT2,0D1Syntax RGr RG Registration Value N/A Units N/A SQRESULT=0 SQ27.96,SQRESULTST1 AC1 DE1 VE25 DA6 GO VE50 DA0 GO EN Value N/A Units secondsSyntax VEr VE Velocity WTexpression= starting input number Summary of Expressions, Operators and Functions Helpful Hints Programming your applicationProgramming Overview Example of Hosted Mode ProgramVariable Names Examples of how to use Built-in Variables Built-in VariablesVariable Name Description of Built-in Variable Type Using Built-in Variable Arowrel Non-Volatile Variables PartsLpnumber Arithmetic Operands and Equations AO15=VOLTAGE + ErrorExamples of incorrect use Instead, you should useIncrement/Decrement Variables Logical OperatorsExpressions Other Programming SamplesSetting an Output=On on-the-fly Create a Message and Read an Input VariableCreate a Menu menu display on keypad display for operator Reading an Analog Input Value Read a 4 Digit BCD number, 2 Digits at a timeGET 4 Bcds Digit BCD=4 Digit BCD+2TW1Operation Indicators Section Troubleshooting2Axis 1 and 2 Indicators Additional Information GeneralAdditional Information Troubleshooting MN1854Serial Communications Problems Troubleshooting MN1854 MN1854 Specifications & Product Data Section Specifications & Product DataIdentification LinStep+ LX 2 P 1 aProtection & Indicators Description General SpecificationsVAC VDCDimensions Optional Keypad 10.08 256.0 Axis Driver 148.394.7 230.1 Specifications & Product Data MN1854 Section CE Guidelines Wiring of Shielded Screened CablesCE Declaration of Conformity EMC Conformity and CE MarkingCE Guidelines MN1854 EMC Wiring TechniqueCit Grounding EarthCable Screens Grounding EMC Installation InstructionsSimulated Encoder Output Cable Grounding Input Signal Cable GroundingEncoder Cable Grounding To ControllerAppendix a Programming TemplateMN1854 Appendix A-1 Appendix MN1854 MN1854 Appendix A-3 122.88 Remote Keypad Mounting Template838 111.25Baldor Electric Company MN1854 01 C&J Baldor Electric CompanyLinStep+ Dual-Axis Microstepping Indexer/Driver