Black & Decker CHS6000, 90504595 instruction manual Important Charging Notes, Functional

Page 5

9051138 02 CHS6000 Hand SAW 8/16/06 11:11 AM Page 5

(1.) Plugging the charger output plug (10) directly into the charging socket (3) of the saw as shown in figure B or, (2) Plugging the charger output plug (10) directly into the mounting bracket (7) as shown in figure C and suspending the saw from the bracket as shown in figure D (see “Hanging the Wall Mounting Bracket”. NOTE: The red LED light will illuminate indicating that the charging process has started.

To charge the tool, follow the steps below:

(3)Plug the charger (6) into any standard 120 Volt 60 Hz electrical outlet.

(4)Let the tool charge initially for 9 hours. After the initial charge, under normal usage, your tool should be fully charged in 3 to 6 hours.

WARNING: When disconnecting the charger from the tool, be sure to unplug the charger from the outlet first, then disconnect the charger cord from the saw.

Important Charging Notes

1.After normal usage, your tool should be fully charged in 3 to 6 hours. If the batteries are run down completely, it may take up to 6 hours to become fully charged. Your tool was sent from the factory in an uncharged condition. Before attempting to use it, it must be charged for at least 9 hours.

2.DO NOT charge the batteries in an air temperature below 40°F (4,5 °C) or above 105°F (+40,5 °C). This is important and will prevent serious damage to the batteries. Longest life and best performance can be obtained if batteries are charged when air temperature is about 75°F.

3.While charging, the charger may hum and become warm to touch. This is a normal condition and does not indicate a problem.

4.If the batteries do not charge properly:

(1)Check current at receptacle by plugging in a lamp or other appliance.

(2)Check to see if receptacle is connected to a light switch which turns power off when you turn out the lights.

(3)Move charger and tool to a surrounding air temperature of above 40 degree F (4,5°C) or below 105 degree F (+40,5°C).

(4)If the receptacle and temperature are okay, and you do not get proper charging, refer to your warranty.

5.The tool should be recharged when it fails to produce sufficient power on jobs which were easily done previously. DO NOT CONTINUE using product with its batteries in a depleted condition.

6.To prolong battery life, avoid leaving on charge for extended periods of time (over 30 days without use). Although continuous charging is not a safety concern, it can significantly reduce overall battery life.

7.The batteries will reach optimum performance after being recharged 5 times during normal usage. There is no need to run the batteries down completely before recharging.

FUNCTIONAL

DESCRIPTION - Figure A

1.On/off switch

2.Lock-off button

3.Charging socket

4.Shoe

5.Blade clamp release lever

6.Charger

7.Wall mounting bracket

8.Saw blade storage

9.LED Charging Indicator

A

4

2

 

5

1

 

 

 

 

3

 

8

 

 

9

6

 

 

 

 

7

 

 

5

Image 5
Contents VEA EL Español EN LA Contraportada Save this Manual for Future ReferenceGeneral Safety Rules for ALL Battery Operated Tools Specific Safety Rules Charging Procedure Figures B,C,D Safety Warnings and Instructions ChargingFunctional Important Charging Notes99051138104595 02 CHS6000 Hand SAW 8/16/06 1111 AM Blade Clamp Release Lever Figure F Trigger Switch Figure EOperating Instructions Battery Removal MaintenanceWood Cutting Metal Cutting Figure GService Information Full TWO-YEAR Home USE Warranty TroubleshootingAccessories See ‘Tools-Electric’ Yellow Pages For Service & Sales Conservez CE Mode Demploi Pour UN Usage Ultérieur Mode D’EMPLOIZone DE Travail Conserver CES MesuresMesures DE Sécurité Relatives À L’ÉLECTRICITÉ Sécurité PersonnelleEntretien Règles DE Sécurité SpécifiquesUtiliser un seul chargeur pour charger Avertissements DE Sécurité ET Directives ChargeRemarques Importantes DE Chargement Procédure DE Charge Figures B,C,DDe la lame Voyant de l’indicateur de charge LED 16/06 1111 AM Coupe DU Bois Installation DU Support MuralDétente Figure E Découpe EN Poche Bois Seulement Figure H Coupe DE Métaux Figure GÉlagage D’ARBRE Conseils Pour LES ProjetsDépannage AccessoiresInformation sur les réparations Conserve Este Manual Para Futuras Consultas Manual DE InstruccionesÁrea DE Trabajo Conserve Estas InstruccionesSeguridad Eléctrica Seguridad PersonalServicio Herramienta se encienda accidentalmenteInstrucciones Y Advertencias DE Seguridad Carga Procedimiento DE Carga Figuras B,C,D Notas Importantes Sobre LA CargaDescripción DE LAS 9051 02 CHS6000 Hand SAW Palanca DE Liberación DE LA Abrazadera DE LA Hoja Figura F Instrucciones DE OperaciónInterruptor Disparador Figura E Cortes EN Metal Figura G Cortes EN MaderaCortes Internos Madera Solamente Figura H Recortes DE ÁrbolesAccesorios Extracción DE LA BateríaDetección DE Problemas GUADALAJARA, JAL CULIACAN, SIN MONTERREY, N.LPUEBLA, PUE MEXICO, D.F02 CHS6000 Hand SAW 8/16/06 1111 AM