Specifications | 38 |
|
|
|
|
Non Grid-Tie Smart Box Electrical Specifications
Description | Rating | Units |
Input |
|
|
Maximum Turbine Voltage | 200 | Volts DC |
Operating input voltage range | Volts DC | |
Maximum input current | 18 | Amps DC |
Maximum input short circuit current | 20 | Amps DC |
|
|
|
Inverter |
|
|
Operating voltage range | Volts AC | |
Operating frequency range or single frequency | Hz | |
Nominal output voltage (ac) | 120 | Volts AC |
Nominal output frequency | 60 | Hz |
Maximum continuous output current | 12.5 | Amps AC |
Maximum continuous output power (ac) | 1500 | VA |
Maximum output fault current (ac) for 3 minutes | 14.5A / 3 min | Amps AC |
Maximum output overcurrent protection (ac) | 20 | Amps AC |
|
|
|
Charge |
|
|
Nominal output voltage (dc) | 24 | Volts DC |
|
|
|
Charger output voltage operation range (dc) | Volts DC | |
Maximum continuous output current (dc) | 60 | Amps DC |
Maximum continuous output power (dc) | 1500 | Watts DC |
Maximum output current (dc) | 60 | Amps DC |
Maximum output fault current (dc) | 62 | Amps DC |
Environment
60
Hz +/- 0.05%
Normal operation temperature range | 0 - 40 | Deg C |
Storage temperature range | Deg C | |
|
|
|
Other |
|
|
GFI Trip | 0.5 | Amps |
Operating Power | <3.5 | Watts |
Output Waveform | Pure Sine | THD > 3% |
Inverter Efficiency | 94.00% |
|
Changer Efficiency | >90% |
|
Charger regulation method | Three Stage: bulk, absorption, float |
|
Manufacturer reserves the right, without notice or liability, to change design and specifications at any time.
DATA SUBJECT TO CHANGE WITHOUT NOTICE
SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev14