Honeywell WT6500 Non Grid-Tie Smart Box Electrical Specifications, Input, Charge, Environment

Page 45

Specifications

38

 

 

 

 

Non Grid-Tie Smart Box Electrical Specifications

Description

Rating

Units

Input

 

 

Maximum Turbine Voltage

200

Volts DC

Operating input voltage range

30-170

Volts DC

Maximum input current

18

Amps DC

Maximum input short circuit current

20

Amps DC

 

 

 

Inverter

 

 

Operating voltage range

120VAC+/-3%

Volts AC

Operating frequency range or single frequency

60Hz+/-0.05%

Hz

Nominal output voltage (ac)

120

Volts AC

Nominal output frequency

60

Hz

Maximum continuous output current

12.5

Amps AC

Maximum continuous output power (ac)

1500

VA

Maximum output fault current (ac) for 3 minutes

14.5A / 3 min

Amps AC

Maximum output overcurrent protection (ac)

20

Amps AC

 

 

 

Charge

 

 

Nominal output voltage (dc)

24

Volts DC

 

 

 

Charger output voltage operation range (dc)

12-30

Volts DC

Maximum continuous output current (dc)

60

Amps DC

Maximum continuous output power (dc)

1500

Watts DC

Maximum output current (dc)

60

Amps DC

Maximum output fault current (dc)

62

Amps DC

Environment

60

Hz +/- 0.05%

Normal operation temperature range

0 - 40

Deg C

Storage temperature range

-30 - 70

Deg C

 

 

 

Other

 

 

GFI Trip

0.5

Amps

Operating Power

<3.5

Watts

Output Waveform

Pure Sine

THD > 3%

Inverter Efficiency

94.00%

 

Changer Efficiency

>90%

 

Charger regulation method

Three Stage: bulk, absorption, float

 

Manufacturer reserves the right, without notice or liability, to change design and specifications at any time.

DATA SUBJECT TO CHANGE WITHOUT NOTICE

SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev14

Image 45
Contents Smartbox Controller Safety Icons Safety InstructionsImportant Safety Instructions General Safety InstructionsLimitations on USE Battery Safety InformationSafety Instructions Safety Instructions Table of Contents Commisioning For Information On See IntroductionSmartbox Controller Major System ComponentsParts Inspection Battery Types Battery OverviewNot to be used Minimum to be usedBattery Selection AC Load Detail and SelectionAmp-hour Ratings Not Recommended Recommended AppliancesIntroduction Smartbox Controller InstallationTurbine Block Diagram System DiagramsSmartbox Controller Diagram MountingRisk of Fire or Explosion Minimum Clearance for Proper Mounting Equipment DamageEXPLOSION/CORROSION Damage Grounding WiringShock Hazard Shock Hazard and Fire HazardTurbine to Wiring DiagramTurbine Current Rating and Wiring Turbine Wiring and DistancesReverse Polarity Damage Turbine Over-current ProtectionBattery Connection Location Battery WiringShock or Fire Hazard Battery Over-current ProtectionAC Output Wiring AC Input WiringAC Output Over-current Protection Turbine Smartbox ControllerJunction BOX Control WiringConnecting the Smartbox Controller Battery SetupEnclosure Internal Wiring Battery Setup ChartWarranty Void Warning To connect the Smartbox ControllerFire and Shock Hazard Smartbox Installation For Information on See Commissioning Process CommissioningCommissioning Process Set the battery type FloodedCheck all connections for polarity Display DescriptionPress Enter to start the turbine Shows if a turbine voltage was foundCommissioning Operation Turbine Operating States IntroductionStarting/Stopping Turbine Viewing Operating StatusTurbine Operating States Controller Energy Consumption StatesTurbine User Stop State System ProtectionCool Down Over Wind SpeedSystem Faults Non Grid-Tie SmartBox Fault SpecificationsFault Description State Required for Fault Navigation Buttons Smartbox Controller Front PanelSystem Menu and Navigation Operations MenuTechnician Menu View Data Menu Battery Setup Menu Operation Specifications Input Non Grid-Tie Smart Box Electrical SpecificationsCharge EnvironmentWindTronics