29 | Operation |
|
|
|
|
Controller Energy Consumption States
•Display On State
The Display state is enabled by pressing any key on the SMARTBOX™ Controller. This state will enable the LCD backlight and cause user information to scroll on the second line of the LCD screen. This state is also active when accessing the menus. If no buttons are pressed, the SMARTBOX™ Controller will automatically switch back to the running state.
•Display Off State
The off state is the default state if the turbine is producing energy from the wind, waiting for the wind, or if any button on the system controller is pressed. The display backlight will be off and no information will scroll. If any faults occur in this state, the fault will be displayed. The controller will maintain this state if the turbine input voltage is greater than 20VDC.
Turbine Operating States
•Turbine Running State
When the turbine is in its running state, the following will be shown on the display and is based on the energy consumption state:
Display - Main Menu Scroll | Description |
|
|
CHARGER: | Displays the charger operating state: |
BULK | Charge is in bulk charge stage |
ABSORPTION | Battery is in absorption stage |
FLOAT/READY | Battery charge cycle complete and ready for use |
STOPPED | Charge cycle has stopped |
FAULT | Reference Fault Table on page 37, Figure 4.3 |
TURBINE: | Displays the turbine operating state: |
STOPPED | Stopped State |
RUN NO WIND | Turbine is running but no wind is present |
RUN WIND | Turbine is running and wind is present |
FAULT STOP | Reference Fault Table on page 37, Figure 4.3 |
AC: | Displays the transfer switch location: |
GRID | AC output is connected to grid |
AC TURBINE | AC output is connected to turbine inverter |
FAULT | Reference Fault Table on page 37, Figure 4.3 |
POWER | Displays the power generated by the turbine |
PRODUCTION | Displays the total accumulated energy generated by |
| the inverter from batteries |
WIND SPEED | Displays measured wind speed |
|
|
|
|
Display - Display Off | Description |
TURBINE RUNNING | Turbine is running with no faults. Back light is off |
PRESS ANY KEY | with no information scroll. |
Figure 4.2 Turbine Running States
•Turbine Fault Stop State
The turbine will enter its Fault Stop state if any faults occur. The turbine will stop operating and the user must clear the faults to restart the turbine. The faults are cleared by pressing ENTER on the SMARTBOX™ Controller control panel. The following will be shown on the SMARTBOX™ Controller LCD screen and is based on
SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev14