SMARTBOX Installation

 

 

 

 

Battery Wiring

The battery charge current is rated at 60 amps and inverter current is rated 72 amps maximum. The recommended wire type is #4 AWG USE-2/RHW-2 or THWN-2, 90 degrees C wire for a SMARTBOX™ Controller-to-battery-enclosure distance of up to

6.3feet. The wire gauge should be increased to #2 AWG wire for a distance of 6.3-10 feet.

Figure 2.7 Battery Connection Location

SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev14

Image 22
Contents Smartbox Controller Important Safety Instructions Safety InstructionsSafety Icons General Safety InstructionsBattery Safety Information Limitations on USESafety Instructions Safety Instructions Table of Contents Commisioning Introduction For Information On SeeMajor System Components Smartbox ControllerParts Inspection Not to be used Battery OverviewBattery Types Minimum to be usedAC Load Detail and Selection Battery SelectionAmp-hour Ratings Recommended Appliances Not RecommendedIntroduction Installation Smartbox ControllerSystem Diagrams Turbine Block DiagramMounting Smartbox Controller DiagramRisk of Fire or Explosion Equipment Damage Minimum Clearance for Proper MountingEXPLOSION/CORROSION Damage Shock Hazard WiringGrounding Shock Hazard and Fire HazardWiring Diagram Turbine toTurbine Wiring and Distances Turbine Current Rating and WiringTurbine Over-current Protection Reverse Polarity DamageBattery Wiring Battery Connection LocationBattery Over-current Protection Shock or Fire HazardAC Input Wiring AC Output WiringTurbine Smartbox Controller AC Output Over-current ProtectionControl Wiring Junction BOXEnclosure Internal Wiring Battery SetupConnecting the Smartbox Controller Battery Setup ChartTo connect the Smartbox Controller Warranty Void WarningFire and Shock Hazard Smartbox Installation Commissioning For Information on See Commissioning ProcessCheck all connections for polarity Set the battery type FloodedCommissioning Process Display DescriptionShows if a turbine voltage was found Press Enter to start the turbineCommissioning Operation Starting/Stopping Turbine IntroductionTurbine Operating States Viewing Operating StatusController Energy Consumption States Turbine Operating StatesCool Down System ProtectionTurbine User Stop State Over Wind SpeedNon Grid-Tie SmartBox Fault Specifications System FaultsFault Description State Required for Fault System Menu and Navigation Smartbox Controller Front PanelNavigation Buttons Operations MenuTechnician Menu View Data Menu Battery Setup Menu Operation Specifications Charge Non Grid-Tie Smart Box Electrical SpecificationsInput EnvironmentWindTronics
Related manuals
Manual 46 pages 4.52 Kb