Trane CNT-SVX07C-EN, Zone Controller, N512 manual Index

Page 80

Index

Electric heat, 1 Face-and-bypass dampers, 1 Outdoor/return air dampers, 1 Rover service tool, 1

Tri-state modulating dampers, 1 Tri-state modulating valves, 1 Two-position valves, 1

Current-sensing switches, 4

D

Dampers Actuators, 5 Exhaust, 41

Face-and-bypass, 1, 21, 46 Modulating outdoor/return air,

43, 46

Outdoor/return air, 1, 21, 41, 43 Supported applications, 1, 21 Tri-state modulating, 1 Two-position control, 46

Data sharing, 48

Dehumidification, 47

Device addressing for BAS communication, 9

Diagnosing operational problems, 63–67

Diagnostics Automatic, 58 Clearing, 58

CO2 Sensor Failure, 60 Condensate Overflow, 59 Discharge Air Temp Failure, 60 Discharge Air Temp Limit, 60 Entering Water Temp Failure, 60 Freeze protection, 60

Generic AIP Failure, 61

Generic Temperature Failure, 61 Humidity Input Failure, 60 Informational, 59

Invalid Unit Configuration, 61 Latching, 58

Local Fan Mode Failure, 61

Local Setpoint Failure, 61 Low Coil Temp Detection, 59 Maintenance (filter change), 59 Manual, 58

Nonlatching, 58 Normal, 61

Outdoor Air Temp Failure, 60 Smart reset, 59

Table, 59

Types, 58

Zone Temp Failure, 59

Dimensional diagram, 3

Dimensions, 2

Discharge air temperature Failure diagnostic, 60 Low limit diagnostic, 60

Discharge air temperature input, 18

Discharge air temperature low limit, 50

Discharge air tempering, 39

DX cooling Operation, 46 Supported application, 21 Troubleshooting, 65

E

Economizing, 19, 45

Electric heat Operation, 47 Supported application, 21 Troubleshooting, 65

Entering water temperature Diagnostic, 60

Input, 17

Sampling function, 40

Equipment supported, 1, 13, 21

Exhaust control, 41

F

Fan

Exhaust, 41

Mode input, 17

Operation, 40

Supply, 41

Troubleshooting, 63

Fan coils, 1, 21

Fan off delay, 49

Fan status

Input, 15

Switching devices, 4

Unit protection, 49

Filter-maintenance timer, 50

Four-pipe operation, 43

Free cooling, see Economizing

Freeze avoidance, 19, 50

Freeze protection, 50

Freeze-protection switch, 4, 14

G

Generic

Binary input, 15

Binary output, 59

Temperature input, 18

Generic AIP failure diagnostic, 61

Generic binary input, 15

Generic binary output, 21

Generic temperature failure diagnostic, 61

H

Heating or cooling mode, 39

Humidity

Input failure diagnostic, 60 Measurement input, 20 Zone sensor, 20

Hydronic cooling, 21

I

Informational diagnostics, 59

Input/output functions, 13–34

Input/output terminal wiring, 7

Invalid unit configuration diagnostic, 61

Isolation valve operation, 46

L

LEDs General, 51

Interpreting green (status), 57 Interpreting red (service), 56 Interpreting yellow

(communications), 57 Location, 51

Local fan mode input failure diagnostic, 61

Local setpoint failure diagnostic, 61

Local setpoint input, 17

LonTalk communication Description, 1 Termination resistors, 9 Wiring and addressing, 9

LonTalk protocol, see LonTalk communication

40

CNT-SVX07C-EN

Image 80
Contents Installation and Operation Tracer ZN521 Zone Controller Page CNT-SVX07C-EN April CNT-SVX07C-EN Tracer ZN521 Zone Controller Installation and Operation CNT-SVX07C-EN Contents Sequence of operations Status indicators for operation and communication Troubleshooting Index Overview and specifications Product descriptionClearances DimensionsStorage environment Plastic-cover model dimensions and clearances Agency listing/compliance Additional componentsTracer zone temperature sensor options Damper actuatorsZone humidity sensor CO2 sensorOverview and specifications Input/output terminal wiring AC-power wiringGeneral wiring information Communication-link wiring and addressing General wiring information Location recommendations Operating environment requirementsMounting recommendations Mounting the Tracer ZN521 zone controllerTypical applications for the Tracer ZN521 zone controller Application SpeedfanMultiple DehumidificationControlValve Economizing HeatElectricBI1 Low-coil-temperature detection Binary inputsBI2 Condensate overflow Binary inputsBI3 Occupancy or generic binary input BI4 Fan statusZN Zone temperature Analog inputsGND Ground terminals Analog inputsSET Local setpoint FAN Fan mode inputAI1 Entering water temperature AI2 Discharge air temperature AI3 Outdoor air temperature or generic temperatureAI4 Universal 4-20 mA AI4 configuration options and associated measurement rangesConfiguration Measurement range AI4 terminal wiring CO2 measurement Binary outputs Generic binary outputBinary output functions Binary output FunctionsWiring requirements and options Overriding binary outputsRequired controller inputs for proper operation Function Input source For more information SeeTwo-pipe hydronic-cooling unit Two-pipe hydronic-heating unit Two-pipe hydronic heating/cooling unit with auto changeover Four-pipe hydronic heating/cooling unit Four-pipe heating/cooling unit with auto changeover Two-pipe heating unit with DX cooling Electric heat unit with DX cooling Electric heat unit Two-pipe heating unit with face-and-bypass damper Two-pipe heating/cooling unit with face-and-bypass damper Four-pipe heating/cooling unit with face-and-bypass damper Input/output functions and wiring for typical applications Power-up sequence Random startOccupied mode Unoccupied modeOccupied standby mode Occupancy modesOccupied bypass mode Timed override controlSimplified zone control Zone temperature controlCascade zone control Heating or cooling mode Discharge air temperingMorning warm-up Morning cool-downEntering water temperature sampling function Fan operationExhaust control Exhaust controlValve operation Modulating valve operationModulating valve calibration Valve control optionsModulating outdoor/return air dampers Two-position valve operationIsolation-valve operation Two-pipe operationModulating outdoor air damper position Economizing free cooling Ashrae Cycle 1 conformanceAshrae Cycle 2 conformance Two-position control of a modulating outdoor air damper Face-and-bypass damper operationDX cooling operation Face-and-bypass, isolation-valve operationDehumidification Electric heat operationBaseboard heat operation Peer-to-peer communication Unit protection strategiesSmart reset Low-coil-temperature protectionFan off delay Condensate overflowFreeze avoidance Filter-maintenance timerFreeze protection discharge air temperature low limit Test button Tracer ZN521 zone controller circuit boardManual output test For non OutputClose damper, air Outdoor Open damper, air Outdoor Step Result BOP1 BOP2 BOP3 BOP4 BOP5 BOP6 BOP7 BOP8 BOP9Service pin button Red LED Service indicatorInterpreting LEDs LED activity ExplanationGreen LED Status indicator Yellow LED Communications indicatorDiagnostics Types of diagnosticsTable of diagnostics DiagnosticsDiagnostic Probable cause Consequences Type Fan unaffectedValved unaffected PositionDamper unaffected Status indicators for operation and communication Fan does not energize Probable cause ExplanationTroubleshooting Valves remain closedValves remain open DX or electric heat does not energizeOutdoor air damper remains closed Outdoor air damper remains openOutdoor air damper remains open Troubleshooting Index NumericsIndex Index Index Page Trane